MODELS DE3, DE4 AND DE5 TROUBLESHOOTING GUIDE
F
PROBLEM: SHUTTLE VAL VE NOT FUNCTIONING PROPERLY
POSSIBLE CAUSE
CHECK
CORRECTIVE ACTION
F1
No power to shutoff
With power on, disconnect
If voltage at #17 and #18, and
solenoid valve.
humidity alarm sensor cable
voltage at #11 and #15, and no
from sensor. This will make
voltage at #15 and #16, relay is
sure unit is not in alarm and
bad. Replace relay.
shutoff valve should be
energized. With voltmeter,
check for line voltage at
shutoff solenoid valve, wires
#15 and #16. If not reading line
voltage, check wires #17 and
#18, then wires #11 and #18.
F2
Coil burned out.
With power on, disconnect
If no magnetic effect can be felt,
humidity sensor cable from
replace coil.
sensor. This will make sure unit
is not in alarm and shutoff valve
should be energized. Check
magnetic field from coil operation.
Hold iron or steel material
(screwdriver end or nail) at top of
coil to feel the magnetic effect,
indicating proper operation.
F3
Valve needs maintenance
If valve leaks with power off or if
Install valve maintenance kit.
kit.
causes F1 and F2 are eliminated,
you may need to install a valve
maintenance kit.