E

PROBLEM: NO ALARM DURING WET AIR CONDITION

POSSIBLE CAUSE

CHECK

CORRECTIVE ACTION

E1

No power to humidistat

With voltmeter, check for line

Make sure there is power to

board.

voltage at "Hot" and "Neutral"

dryer. Check wiring diagram

terminals on humidistat board.

for correct wiring. Check

Also check for line voltage at

continuity of wires.

"Common" and "Neutral".

E2

Sensor cable connection.

Check cable connections at

Reconnect

sensor and at humidistat board.

E3

Bad sensor.

Remove air pressure from dryer.

Replace sensor.

With sensor cable connected and
power on, unscrew brass hex nut
at bottom of sensor housing. Blow
gently on sensor. The moist air
from your breath should cause
the alarm to sound.

E4

Bad humidistat board.

Press red "Push to Test" button on

Replace humidistat board.

humidistat board. Alarm should
sound.