Initial start up, Start up procedure, Engine generator set only – Winco ULPSS12H4W/E User Manual

Page 13

Advertising
background image

3

075-00

60706-208

INITIAL START UP

******************

***** WARNING *****

******************

DO NOT jump start these generator sets. Starting

these units on a low battery by jump starting them

will cause damage to the engine control module.

Use the following checklist to verify correct in-

stallaion before starting the engine:

Engine oil. Check level & fill as required with

proper grade/quantity. Refer to engine owners

manual for proper levels and types.

Unit mounting base properly bolted down.

Clearance for service and maintenance on all

sides.

Proper fuel line material and size.

All fuel line connections tight.

Fuel line protected and a moisture trap in

stalled (may be required for NG).

LP/NG pressure OK. 4-6 oz. (7- in. WC).

Battery connections clean and tight.

Battery fully charged.

All AC and DC wiring installed and properly

protected.

After completing the above checklist, the generator

set is ready for the initial start-up test.

START UP PROCEDURE

Engine Generator Set only

Move the left hand toggle switch from OFF to the

ON position. The alarm light should go out. Next

move the right hand toggle witch from the AUTO to

the RUN position. You should hear the fuel solenoid

engage at this time. Next lift the toggle switch to the

START position and hold. The engine starter should

engage and the engine will start. As soon as the en-

gine starts release the toggle switch and it will return

to the run position. If the engine does not start after

5 seconds release the switch and let the starter rest

for 5 seconds and re-attempt to start. If the unit still

will not start, consult the troubleshooting guide in the

back of this manual.

WIRE #

PURPOSE

RECOMMEND

COLOR

# 5

Battery Positive

Black

# 1

Battery Negative

White

# 24

Fuel Solenoid

Red

# 22

Start

Orange

These wire colors are a recommendation only. The

wires terminate on TB7 as follows:

WIRE #

COLOR

TB7 TERMINAL

# 5

Black

# 3

# 1

White

# 2

# 24

Red

# 4

# 22

Orange

# 7

Jumpers will need to be installed as follows:

WIRE #

COLOR

TB7 TERMINAL

# 5

Black

# 3 & # 5

# 5

Black

# 5 & # 8

The following is an optional way to interconnect the

Generator and the Transfer Switch. the wires termi-

nate on TB7 terminal as follows:

WIRE #

COLOR

TB7 TERMINAL

# 1

White

# 2

# 24

Red

# 4

# 22

Orange

# 7

The following leads are wire-nutted together:

WIRE #

COLOR

FROM

# 5

Black

Generator

# 5

Black

TB7 # 3

# 5

Black

TB7 # 5

#5

Black

TB7 # 8

Advertising