ESPECIFICACIONES (1K-HB / 2K-HB / 3K-HB)

(1/2)

OPTIMA (HB)


INPUT / ENTRADA

Freq. Range / Rango Frecuencia

Slew Rate / Seguimiento de F.
Surge Immunity Level

Output Regulation / Rango de Salida

Freq. Conversion / Conversión Frec.
EPO /Apagado Emergencia
Progammable Outputs / Salidas Prog.

Eco Mode

AC Mode / Modo Normal
Battery Mode / Modo Batería
Output Shortcircuit / Cortocircuito en Salida

Type / Tipo
Cap. & Qty
Recharge Time / Recarga
Charging Voltage / Voltaje de Carga
Charging Amps / Corriente de Carga
EXT. BATT CABINETS (Optional) - BATERIAS EXTERNAS (opcionales)
Standard EXT-BATT pack
INDICATORS / INDICADORES

LCD

UPS status, Load level, Battery, Input/Output voltage, Discharge timer, and Fault conditions

Estado del UPS, Consumo, Baterías, Voltaje Entrada/Salida, Autonomía, Diagnostico Fallas

ALARM / ALARMAS
Alarm Beep / Alarma Sonora:

Battery Mode, Low batt., Overload, UPS Failure / Modo Batería, Baja batería, Sobrecargas, Falla

4 Hours for 90% capacity / 4 Horas para recuperar el 90% de carga

27.4Vdc

54.7Vdc

82.1Vdc

1.0 A (Max.)

x

12V-9Ah x 8

12V-9Ah x 12

Full Protection for all outlets / Protección en todas las salidas

105%~110%: 10 min: shutdown / 110%~130%: 1 min: shutdown / >130% : 3s: shutdown

BATTERIES / BATERIAS

Sealed Lead Acid VRLA-AGM / Sellada de Libre Mantenimiento VRLA-AGM

12V/9AH x 2

12V/9AH x 4

12V/9AH x 6

Battery Mode / Modo Batería

> 86%

> 88%

> 88%

OVERLOAD/ SOBRECARGA

105%~110%: 10 min to Bypass / 110%~130%: 1min to Bypass / >130% : 3s: bypass

PEAK EFFICIENCY / EFICIENCIA MAX.

> 93%

> 93%

> 93%

AC Mode / Modo AC

> 89%

> 90%

> 90%

N

N

N

N

N

N

AC to Inverter / Tiempo AC a Inversor

0 ms

Waveform / Forma de Onda

Pure Sinewave / Sinusoidal Pura

N

N

N

+/-1% (in Batt. mode)

Frequency / Frecuencia (Batt. Mode)

(*N3) 50 Hz +/- 0.25 Hz - 60Hz +/- 0.3 Hz

Current Crest Ratio / Factor de Cresta

3:1 @ 100% load

Harmonic Distortion /
Dist. Armónica (THDv)

< 3% @ Linear Load / Carga Lineal

<6% @ No Linear Load / Carga no Lineal

Input THDi / THDi de Entrada

< 7% @ 100% load

1 Hz / s

> 7KV (EN61000-4-5)

OUTPUT / SALIDA
Voltage Output / Voltaje de Salida AC

(*N1) Model 120V: 110/115/120/127Vac - Model 220V: 208/220/230/240Vac

Range / Rango - Vac (Models 220V):

Model 220V: 160Vac-290Vac (load @ 100%)

Model 220V: 110Vac-300Vac (load @ 50%)

40 Hz - 70Hz

Phase / Fases

Single phase with ground / 1 fase + Tierra

Power Factor / Factor de Potencia

> 0.99 @ 100% load

Capacity / Capacidad (W)

800W

1600W

2400W

Range / Rango - Vac (Models 120V):

Model 120V: 85Vac -145Vac (load @ 100%)

Model 120V: 55Vac -150Vac (load < 50%)

ONLINE UPS (1/2)

1K-HB

2K-HB

3K-HB

Capacity / Capacidad (VA)

1000VA

2000VA

3000VA