Table iv-heating performance pressures, Table v-cooling performance pressures – Carrier 542E User Manual

Page 9

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

TABLE IV-HEATING PERFORMANCE PRESSURES

Air Temp at

Indoor Coil

Inlet |°F DB)

Pressure

Designation

(Psig)

54ZED24

542E030

542E036

Air Temperature at Outdoor Coil F°DB

Air Temperature at Outdoor Coii °FDB

Air Temperature at Outdoor Coil °FDB

60

50

40

30

20

10

0

-10

60

50

40

30

20

10

0

-10

60

50

40

30

20

10

0

-10

65

High Side

250

229

209

190

172

155

140

127

238

218

201

184

169

155

144

134

232

214

198

183

170

158

149

142

Low Side

69

59

49

41

33

25

18

14

71

60

50

41

32

24

18

13

64

52

46

38

31

25

18

13

70

High Side

268

243

220

199

180

162

147

134

251

231

211

195

179

165

153

142

247

230

213

198

184

171

161

152

Low Side

70

60

50

42

34

26

19

15

72

61

51

42

33

25

19

14

65

53

47

39

31

25

19

13

75

High Side

280

256

233

211

190

172

155

140

266

246

226

207

190

176

162

151

261

243

225

209

195

182

171

162

Low Side

71

61

51

43

35

27

20

16

73

62

52

43

34

26

20

15

66

54

48

40

32

26

19

14

Air Temp at

Indoor Coil

Inlet (°FDB|

Pressure

Designatiun

IPsig)

542E042

542E048

5420060. A 542E060

Air Temperature at Outdoor Coil °FDB

Air Temperature at Outdoor Coll "FOB

Air Temperature at Outdoor Coil °FDB

60

50

40

30

20

10

0

-10

60

50

40

30

20

10

0

-10

60

50

40

30

20

10

0

-10

65

High Side

254

234

216

193

171

159

148

136

262

237

214

193

174

158

144

134

268

238

210

186

166

151

142

136

Low Side

71

62

50

42

32

24

18

14

64

56

48

40

33

26

19

13

66

56

47

39

32

24

19

13

70

High Side

268

250

230

205

183

169

156

144

278

251

226

204

184

166

154

146

284

252

224

198

178

164

154

146

Low Side

72

63

51

43

33

25

18

14

65

57

49

41

34

27

20

13

67

57

48

40

32

25

19

13

75

High Side

283

266

243

218

194

180

166

153

290

266

242

220

201

184

169

158

298

268

238

212

190

1/4

162

156

Low Side

73

64

52

44

34

26

19

14

66

58

50

42

35

28

21

14

68

58

49

41

33

25

20

14

TABLE V-COOLING PERFORMANCE PRESSURES

Air Temp at

Indoor

Coil

Inlet (°FWB)

Pressure

Designation

IPsigI

542E024

542E030

54ZE035

Air Temp at Outdoor Coil |°F DB|

Air Temp at Outdoor Coil (°FDBI

Air Temp at Outdoor Coii l°F OBI

65

70

75

80

85

90

95

too

105

110

55

70

75

80

85

90

95

100

105

110

55

70

75

80

85

90

95

100

105

110

55

High Side

157 174 190 207 224 240 258 276 293 313 150 166 181 196 212 226 246 264 282 302 182 196 211 227 242 259 276 294 312 332

Low Side

58

59

60

61

62

63

64

66

67

68

60

62

63

65

67

69

71

73

75

77

67

69

70

72

74

75

76

78

79

81

60

High Side

162 179 195 212 228 244 261 279 296 315

153 169 185 200 216 230 250 268 286 306 185 199 215 231 246 263 280 298 316 336

Low Side

64

65

66

67

68

69

70

71

73

74

63

65

66

68

70

72

75

77

79

81

69

71

72

74

76

77

79

80

82

83

65

High Side

168 185 200 216 232 247 264 282 298 317

157 173 188 204 220 235 255 273 291 311 188 203 219 235 251 268 285 303 321 341

Low Side

70

71

72

73

75

76

77

78

79

80

67

69

70

72

74

76

79

81

83

85

71

73

74

76

78

80

81

83

85

86

70

High Side

173

191

206 223 239 253 270 288 304 324 160 177 192 208 224 240 259 277 295 315 192 207 223 239 255 273 290 308 326 346

Low Side

77

78

79

80

81

82

83

84

86

87

70

72

74

76

78

80

83

85

87

89

74

76

77

79

81

83

84

86

88

89

75

High Side

175 192 209 227 242 260 278 294 315 336 164 180 196 212 228 244 264 282 300 320 196 212 228 244 260 278 296 314 332 352

Low Side

84

85

86

87

88

90

91

93

94

95

74

76

78

80

82

84

87

89

91

93

79

81

83

84

86

88

89

91

93

9b

Air Temp at

Indoor

Coil

Inlet l°FWBI

Pressure

Oesignation

(Psig)

542E042

542E048

5420060 S 542E060

Air Temp at Outdoor Coil l°F 08)

Air Temp at Outdoor Coil l°F 08)

Air Temp at Outdoor Coil (°F0BI

55

70

75

80

85

90

95

100

105

110

65

70

75

80

85

90

95

100

105

110

65

70

75

80

85

90

95

100

105

110

55

High Side

165 179 192 206 222 237 254 270 289 308

178 192 207 224 238 255 272 291 308 330 176 189 202 217 233 249 266 283 300 320

Lew Side

60

62

63

65

67

68

70

72

74

75

61

62

63

65

66

68

70

72

74

76

59

61

62

63

65

6/

68

/0

/2

/4

60

High Side

169 183 196 210 226 241 258 275 293 312

183 197 212 229 243 260 277 296 314 335 180 193 207 222 237 254 270 287 305 324

Low Side

64

66

67

69

70

72

74

75

77

79

65

66

67

69

70

72

74

76

78

80

63

65

66

6/

68

/0

/1

/3

/5

n

65

High Side

173 187 201 215 231 246 263 280 298 317

188 203 218 235 249 266 283 302 320 340 185 198 212 227 242 259 275 292 31U 329

Low Side

68

69

71

73

74

76

78

79

81

83

69

70

71

73

74

76

78

80

82

84

67

69

70

/1

/2

/4

/5

/6

/8

80

70

High Side

177 191 205 220 235 251 268 285 303 322

193 208 223 240 254 271 288 307 326 345 191 205 219 234 250 266 283 301 319 338

Low Side

72

73

75

77

78

80

82

83

85

87

73

74

75

77

78

80

82

84

86

88

71

73

74

/5

I I

/9

80

81

83

85

75

High Side

181 196 210 225 240 256 273 290 308 327

198 214 229 246 260 277 294 312 332 350 198 212 227 242 258 274 292 310 328 346

Low Side

76

77

79

81

82

84

86

87

89

91

77

78

80

81

83

84

86

88

90

92

76

77

79

80

82

84

85

8/

89

91

2. Place SYSTEM switch in COOL position and FAN

switch in AUTO position. Set thermostat cooling control
below room temperature to start cooling cycle. Observe
that compressor, outdoor fan, and indoor blower motors
start. Observe that unit shuts down when control set­
ting is satisfied. Wait 5 minutes for pressures to

equalize.

3. Place SYSTEM switch in HEAT position, and leave

FAN switch in AUTO position. Increase thermostat
heating control setting gradually until thermostat
“calls” for heat. Observe that compressor, outdoor fan,
and indoor blower motor start. If supplemental electric
heater is being used in the system, increase thermostat
heating control setting an additional 6 degrees. Observe
that the supplemental electric heater energizes. Set
control setting below room temperature, and observe
that heater deenergizes and that heat pump shuts down.

4. If supplemental electric heater is being used in the

system, leave FAN switch in AUTO position, SYSTEM
switch in HEAT position, and move emergency heat
switch from NORM, position to EM. HT. position. Set
thermostat control setting above room temperature to

start heating cycle. Observe that all supplemental
electric heat is energized, that indoor blower motor
starts, that emergency heat indicator bulb lights, and
that compressor and outdoor fan do not start. When con­
trol setting is satisfied, observe that heater deenergizes

and that blower motor stops; however, indicator light
should remain on as long as emergency heat switch is in
EM. HT. position.

5.

If autochangeover thermostat P/N 34427DP115 is

being used, place both SYSTEM and FAN switches in
AUTO position. Observe that heat pump operates in
heating mode when heating control selector is set above
room temperature, and operates in cooling mode when
cooling control selector is set below room temperature.

B. Checking and Adjusting Refrigerant Charge

The refrigerant system is fully charged with R-22
refrigerant, tested, and factory-sealed. For most applica­
tions, the factory charge is the correct amount for the best

performance; however, this charge rnay require a slight
adjustment to attain rated performance.

-

9

-