The 38qe system software and safety devices, Table 2—accessory parts list – Carrier 38QE User Manual

Page 2

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

domestic water heating control box emd domestic water
heating tank temperature sensor are supplied to control the

electric domestic water heating tank. The water heating is
accomphshed by pumping cold water from the cold water
inlet pipe at the top of the domestic water tank, through the
38QE refrigerant-to-water heat exchanger, and back into
the bottom of the tank.

The variable speed compressor operation allows the 38QE
system to control its output capacity to match the required
load through a wide range of outdoor temperatures and
operating modes.

Specially designed mating 40QE indoor units provide vari­
able airflow control which is increased and decreased along

with the compressor speed. This feature, along with an elec­
tronic expansion device, provide a level of comfort pre­
viously unavailable for the home. It also enhances system
efficiency and provides much quieter operation them conven-
tioneil systems during most periods of operation.

The 38QE/40QE system has many other designed in com­
fort and efficiency features including:

Carrier/Parker

Home-Zone®

thermostat

and

damper

options—to provide separate temperature control in up to
four areas.

Humidity control—add the optional humidistat to activate
special compressor and fan control which improves moisture
removal as needed. Humidistat plus humidifier also controls
moisture addition in the heat mode.

Air cleaning—connections provided for automatic control of
optional electronic air cleaner.

Utility demand limit interface—allows owner participation
in incentive programs offered by utilities for peak load con­
trol, where available.

Unique defrost—the high temperature of the water in the
home’s hot water tank is used as the heat source for the
defrost cycle, rather than cooling the indoor air as with tra­
ditional units. In addition, demand type defrost control pro­
vides defrost when, and only when, it is required.

The 38QE/40QE system is available in capacity sizes shown
in Table 1. Accessories supplied with the system and other
available accessories are shown in Table 2.

APPLICATION LIMITATIONS

The 38QE system software and safety devices

Eire

designed

to prevent equipment operation under conditions that do
not comply with the application hmitations.

The 38QE product has certEun application hmitations which
are hsted below:

1

.

The 38QE compressor section and outdoor section are
to be matched to the specifically designed 40QE indoor
fan coil section. Permitted system configurations are
shown in Table 1.

Table 1—Carrier Approved 38QE Systems

SYSTEM CAPACITY

2 TON

3TON

INDOOR COMPRESSOR SECTION

38QE024300

38QE036300

OUTDOOR FAN-COIL SECTION

38QE924300

38QE936300

INDOOR FAN-COIL SECTION

40QE024300

40QE036300

25 ft maximum vertical rise allowable

2

.

3.

The 38QE can only be used with Carrier/Parker Home-
Zone® thermostats. Monitor thermostat and slave ther­
mostat model requirements are given in Table 2. All
thermostats must be properly configured and pro­
grammed in order to obtain normal system operation.
The 38QE should not be used with systems containing

more than four (4) independently dampered zones. Use

6.

of the bypass controUer accessory is required for aU

zone apphcations.

4. The system wiU not operate in the cool mode at outdoor

temperatures below 45 F, and is not compatible with
tie Carrier Motormaster low-ambient control

; accessory. /

5, §The systern wiU not operate in the heat mode at out­

door ternperatures above 75 F.
The compressor section must be located in a non-
freezing area because of water containing components.
Maximum air temperature surrounding the compressor
section must not exceed 105 F because of cooing
required for electronic controls.
The compressor section is designed to be installed on a
sohd mounting pad such as concrete. Do not install
compressor section in an attic, on a wall, or suspended
from a ceiling.
Refrigerant line lengths are hmited to 50 ft total maxi­

mum, with 25 ft maximum vertical rise between indoor

and outdoor units.

9. For improved domestic water heating, locating the

compressor section within 15 ft of the domestic water
tank is desirable.

7.

8

.

Table 2—Accessory Parts List

ACCESSORIES SUPPLIED WITH COMPRESSOR SECTION

ORDERING NUMBER

DESCRIPTION

313204-701

Water Heater Control Box

313288-710

Water Temperature Sensor

Assembly

313243-201

Comp. Section Base Pad

ACCESSORIES REQUIRED OR RECOMMENDED

Zones

ORDERING NUMBER

DESCRIPTION

Singl

Mult

HT2000

Homezone Monitor Stat w/

clock

RQ

RQ

HZS (Version 2.7 or

higher)

Homezone Slave Stat

RQ

ZD-06,08,10,12,14,16

RD0810,0814,0818,0824

BCE

Round Dampers 6" thru 16"

RQ

Rectangular Damper 8x10

thru 24

Bypass Controller

RQ
RQ

TSR01

Relay Pack-Power Supply

RQ

PS02/PS01

Duct Pressure Sensor

RQ

PSPOO

Static Pressure Plok-up

RQ

RDS

Remote Duct Sensor

OP

OP

RRS

Remote Room Sensor

OP

OP

PCA-223

Plenum Cable—22 AWG, 3

)

conduc

RC

RC

PCA-225

Plenum Cable—22 AWG, 5

conduc

RC

RC

HL38MG026

Humidistat

RC

RC

Humidifier (49BF/FH/WS)

RC

RC

__

Electronic Air Cleaner (31

MPI

RC

RC

38TH900011

SX)

Outdoor Support Foot Kit, 4

in.

Outdoor Snow Rack, 18 in.

OP

OP

38YH900011

OP

OP

38YH900021

(024)

Outdoor Snow Rack, 18 in.

OP

OP

P504-8163S

(036)

Bi-flow Filter-Drier

RQ

RQ

HT01AX220

Transformer 40va

RQ

RQ—Required for installations.
RC—Recommended for installations.

OP—Optional for installations.

10. System is designed to work with conventional residen­

tial sized electric water heating tanks only. NOTE: The
38QE should be installed with electric water heater
tanks that have two connections leading to the bottom
of the tank, as shown in Fig. 7a (cold water in, drain). If
only one connection to bottom of tank, install a preheat
tank, as for gas water heaters. Fig. 7b. For installation
with a gas water heater, a water preheat tank must be
installed.

i ;

<@)