Fig. 4—indoor compressor section, A caution, Step 4 – Carrier 38QE User Manual
Page 4
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
SHIPPING WGT.
A
B
C
D
E
F
USE WITH
UNIT
SERIES LBS.
Kg.
(IN.)
(mm)
(IN.)
(mm)
(IN.)
(mm)
(IN.)
(mm)
(IN.)
(mm)
(IN.)
(mm)
OUTDOOR SECTION
38QE024
0
230
104.3
3/8
9.53
3/8
9.53
3/4
19.05
3/4
19.05
7/8
22.23
7/8
22.23
38QE924
38QE036
0
240
108.8
3/8
9.53
3/8
9.53
3/4
19.05
3/4
19.05
7/8
22.23
7/8
22.23
38QE936
Fig. 4—Indoor Compressor Section
wiring and for servicing the unit (see Fig. 4). Do not exceed
maximum total pipe lengths.
Mount indoor compressor section on a rigid, sohd platform
or concrete floor. Insert the asphalt impregnated felt pad
(factory supplied in container) between the unit basepan and
moimting surface to provide fuU unit support and for vibra
tion attenuation. Do not use vibration isolators under cor
ners of basepan.
Install unit to permit adequate clearance for service on all
sides of the unit. A heat sink which is used to provide elec
tronic component cooling is located at the lower right side
of the rear panel. This heat sink protrudes from the rear
panel. This area should always remain clear of obstructions.
Do not enclose this area, in any manner. Failure to provide
proper ventilation can cause equipment to malfunction.
A CAUTION
To prevent freezing of water piping, do not expose the
38QE indoor compressor section to ambient tempera
tures below freezing.
Step 4—
Install Domestic Water Heater Control Box.
The domestic water heater control box allows the 38QE
heat pump to control the domestic water heating function.
The tank elements are controlled by the 38QE such that the
water heating is performed by the heat pump when possible
and the tank elements are disabled.
Locate the control box adjacent to the Domestic water heat
ing tank. The box will be wired in the branch circuit that
»!