Table 6—field charging table—fixed restrictor – Carrier 50QQ User Manual

Page 10

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Table 6—Field Charging Table—Fixed Restrictor

HEATING OPERATING PRESSURES PSIG (Pressures at High and Low Side Service Ports)

MODEL

INDOOR

OUTDOOR TEMPERATURE (F) DRY BULB

50QQ

DRY BULB (F)

60

50

40

30

20

10

0

-10

65

High

217

202

189

178

168

157

149

140

Low

77.2

65

53.8

43.7

34.7

26.8

19.7

12.6

018

70

High

232

217

203

192

181

169

158

147

Low

77.8

65.4

54.2

44

35

27

19.8

12.9

75

High

248

232

218

205

195

184

174

165

Low

78.4

65.9

54.9

44.4

35.2

27.3

21.1

13.2

65

High

219

204

191

179

171

161

150

139

Low

72.1

60.4

50.2

40.8

32.5

25.1

18.4

11.7

024

70

High

235

219

205

194

183

174

164

154

Low

72.6

60.9

50.5

41.2

32.9

25.4

18.7

12

75

High

251

235

221

209

196

185

176

165

Low

73.2

61.4

51

41.6

33.2

25.6

18.9

12.1

65

High

219

203

190

179

168

153

150

141

Low

70.5

58.9

48.7

39.8

31.9

24.7

18.1

11.6

030

70

High

235

219

205

195

184

170

158

145

Low

71.1

59.4

49.2

40.2

32.2

24.9

18.3

11.7

75

High

250

235

222

208

196

186

176

167

Low

71.5

59.9

49.7

40.6

32.5

25.2

18.6

11.9

65

High

218

202

190

180

172

161

152

142

Low

70.9

59.1

48.8

39.8

31.9

24.6

18.1

11.6

036

70

High

231

216

202

192

186

174

163

153

Low

71.4

59.6

49.3

40.1

32.2

24.9

18.3

11.7

75

High

246

230

216

205

198

187

178

169

Low

72

60.1

49.7

40.5

32.5

25.2

18.5

11.9

65

High

212

197

184

172

162

153

144

135

Low

69.6

58.1

48

39.2

31.5

24.4

18

11.6

042

70

High

226

211

197

185

174

164

155

145

Low

70.2

58.7

48.6

39.7

31.9

24.7

18.3

11.8

75

High

241

225

211

198

187

176

165

155

Low

70.7

59.2

49.1

40.2

32.3

25

18.5

12.1

65

High

315

200

186

174

163

154

145

136

Low

67.7

56.5

46.7

38.1

30.5

23.7

17.5

11.3

048

70

High

229

213

200

187

175

164

154

144

Low

68.3

57.1

47.2

38.6

31

24

17.8

11.5

75

High

243

227

213

200

189

177

167

156

Low

69

57.7

47.7

39

31.4

24.3

18.1

11.8

65

High

214

199

185

174

163

155

145

136

Low

65.2

54.2

44.7

36.4

29

22.5

16.6

10.8

060

70

High

228

213

199

187

175

164

155

146

Low

65.8

54.8

45.2

36.9

29.5

22.9

16.8

10.8

75

High

243

227

213

200

189

178

168

158

Low

66.4

55.4

45.7

37.3

29.9

23.2

17.1

11.0

NOTE: Add charge if pressures are low Bleed out charge if pressures are high. Allow ± 5 psig tolerance on high-side pressure.

B

COOLING DESIRED SUPERHEAT TEMP (F)

(Measured at Low-Side Service Port)

OUTDOOR

DBT

EVAPORATOR AIR INLET WBT (F)

DGT(F)

54

56

58

60

62

64

66

68

70

72

74

76

60

12

15

18

21

24

27

30

33

36

38

40

43

65

10

13

16

19

21

24

27

30

33

36

38

41

70

7

10

13

16

19

21

24

27

30

33

36

39

75

if

6

9

12

15

18

21

24

28

31

34

37

60

*

*

5

8

12

15

18

21

25

28

31

35

85

■¥

*

«

*

8

11

15

19

22

26

30

33

90

*

*

*

*

5

9

13

16

20

24

27

31

95

*

*

*

*

6

10

14

18

22

25

29

100

*

«

*

*

*

8

12

15

20

23

27

105

*

*

*

5

9

13

17

22

26

110

«

*

*

«

*

*

*

6

11

15

20

25

115

*

*

«

*

*

*

*

8

14

18

23

REQUIRED SUCTION TUBE (F) VS. DESIRED

SUPERHEAT (F)

(Measured at Low-Side Service Port)

DESIRED

SUPERHEAT

*Do not attempt to charge system under these conditions or refrigerant
slugging may occur
NOTE: Add charge if actual superheat temperature is higher than chart

value. Remove if lower Allow ± 3 F for tolerance.

Unit is factory charged with R-22 in accordance with amount shown
on rating plate. This chart is intended for usage when minor unit
charge adjustments are required. For large charge adjustments, evac­
uate unit and weigh in charge according to unit rating plate. Best per­
formance will be achieved when unit operates with a suction gas

superheat at compressor inlet of 5 F at normal rating conditions of
Air Conditioning and Refrigeration Institute (ARI). This chart may be

used to approximate the charge if ARI rating conditions cannot be

obtained. ARI rating conditions are 95 F db outdoor. 89 F and 67 F
wb indoor. See Table 4 for required indoor airflow rates. Charge unit
with outdoor fan operating only on high speed.

SUCTION OR LOW-SIDE PRESSURE (psig)

AT SERVICE PORT

TEMP (F)

61.5

64.2

67.1

70

73

76

79.2

82.4

85.7

0

35

37

39

41

43

45

47

49

51

2

37

39

43

43

45

47

49

51

53

4

39

41

43

45

47

49

51

53

55

6

41

43

45

47

49

51

53

55

57

8

43

45

47

49

51

53

55

57

59

10

45

47

49

51

53

55

57

59

61

12

47

49

51

53

55

57

59

61

63

14

49

51

53

55

57

59

61

63

65

16

51

53

55

57

59

61

63

65

67

18

53

55

57

59

61

63

65

67

69

20

55

57

59

61

63

65

67

69

71

22

57

59

61

63

65

67

69

71

73

24

59

61

63

65

67

69

71

73

75

26

61

63

65

67

69

71

73

75

77

28

63

65

67

69

71

73

75

77

79

30

65

67

69

71

73

75

77

79

81

32

67

69

71

73

75

77

79

81

83

34

69

71

73

75

77

79

81

83

85

36

71

73

75

77

79

81

83

85

87

38

73

75

77

79

81

83

85

87

89

40

75

77

79

81

83

85

87

89

91

NOTE: Measure suction tube (F) with accurate superheat thermocouple
or thermistor-type thermometer.

FINAL DISPOSAL: CAUTION—CAREFULLY RELIEVE REFRIGERANT
PRESSURE WITHIN UNIT BEFORE FINAL DISPOSAL

10