How to convert the range for use with lp gas, Step 1, Convert the pressure regulator for lp gas – Sears KENMORE 73318 User Manual

Page 12: Step 2, Convert surface burners for lp gas

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

HOW TO CONVERT THE RANGE FOR USE WITH LP GAS

WARNING: Do not remove the pressure regulator from the range.

Step 1

Convert The Pressure Regulator
For LP Gas

1. Remove the cooktop and locate the pressure regu­
lator at right rear of the range

2. Determine Viihich figure. A, B. or C, is appropriate
for your regulator type.

If it is regulator A:

1. Use a coin to remove the cap from the pressure regulator.

2. Turn the cap over and engage it in the slots. LP
should now be visible on the top of the cap.

If it is regulator B:

1. Unscrew the plastic-protected hex-nut cap assem­
bly from the top center of the regulator.

2. Carefully pry the protective plastic cap off the
threaded metal cap. Gently pull the plastic washer off
the other threads.

3. Replace the plastic cap onto the threaded end dis­
playing the gas type you desire. Press the plastic
washer onto the remaining threads.

4. Reinsert the cap assembly into the regulator. Do
not overtighten, but ensure the seating of the washer.

if it is regulator C:

1. Remove cap and forcibly snap out plastic plunger

from bottom of cap.

2. Turn plunger over and forcibly snap back in original
location. Note: Plunger must snap into position; the
gas type you are converting to must be visible on
lower side of plunger.

3. Reinsert the assembly into the regulator.

^

Step 2

Convert Surface Burners For LP Gas

1. Lift cooktop.

2. Lift burner assemblies straight up and set aside to gain access to surface

burner spuds.

3. With a 5/16" wrench, remove each of the four brass spuds on the surface
burner gas inlet tubes and replace them with the red-tinted LP gas spuds
mounted in a holder at the right rear of the range, above the regulator. (Mount

the brass natural gas spuds in this holder.) To prevent leakage, make sure
spuds are securely screwed into gas inlet tubes..

4. Replace the burner assemblies.

5. Keep the natural gas spuds with your range so yoi! have them if you move
or get a natural gas hook-up.

(continued next page)

t«vsr shown clossd-

BOTATE OBEN

11

Advertising
This manual is related to the following products: