Clean air intake screen, Engine spark plug, Fuel filter – Generac Power Systems 00802-3 User Manual

Page 12

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

• Remove air cleaner cover, then remove paper filter.

• Clean air filter by gently tapping it on a solid surface. If

the filter is too dirty, replace it with a new one. Dispose of

the old filter properly.

• Clean air cleaner cover then insert new paper filter into

cover and assemble to the base of the air cleaner.

CLEAN AIR INTAKE SCREEN

Clean all foreign material from the air intake screen
(Figure 6) at lease once every 100 hours of operation.
Clean more often if necessary.

Inspect the area around the generator exhaust muffler
periodically and remove all grass, leaves, dirt, etc.

from this area.

Figure 6 — Clean Air Intake Screen

ENGINE SPARK PLUG

Clean engine spark plug and set gap to 0.030 inch
^.76mm) every 100 hours of operation (Figure 7).
Clean by scraping or wire brushing and washing with
commercial solvent. DO NOT BLAST CLEAN SPARK
PLUG.

Figure 7 — Setting Gap on Spark Plug

CAUTION; Sparking can occur if wire terminal

does not fit firmly over spark plug terminal end. If

necessary, reform wire terminal to obtain a tight fit.

FUEL FILTER

Remove and replace fuel filter (Figure 8) every 100

hours of operation or once each year, whichever
occurs first.

Figure 8 — Fuel Filter

10

Advertising