Checking engine oil level, Change engine oil, Engine air cleaner – Generac Power Systems 0661-5 User Manual

Page 11: Checking engine oil level change engine oil, Maintenance

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

MAINTENANCE

This section includes information about simple main­
tenance which includes the following tasks:
• Checking engine oil level.

• Changing engine oil.

• Changing oil filter.

• Changing the air cleaner.

• Cleaning the air intake screen.

• Cleaning spark plug.

• Cleaning fuel filter.

CHECKING ENGINE OIL LEVEL

Check engine crankcase oil level at least every eight
hours of operation, or before each use (Figure 3).

• Be sure the generator is as level as possible.

• Remove oil dipstick and wipe dry with clean, lint-free

cloth.

• Install and tighten oil dipstick, then remove again.

• Oil should be at dipstick FULL mark. If necessary, add

the recommended oil to the FULL mark only. DO NOT

FILL ABOVE “FULL’ MARK.

• Install and tighten oil dipstick cap before operating the

engine.

NOTE: See “Engine Oil Requirements” on Page 8 for
recommended oils.

Figure 3 — Oil Dipstick and Fill Tube

Install and tighten dipstick cap before operating engine.

Figure 4 — Location of Oil Drain Plug and Filter

CHANGE ENGINE OIL

Change engine oil after the first 8 hours of operation.
Thereafter, change oil every 50 operating hours.
Change oil more frequently if operating consistently

under heavy load or at high ambient temperatures.

• Warm up engine for at least five minutes, then shut down.

• With engine still warm from running, clean area around

oil drain plug and remove oil drain plug (Figure 4). Drain
oil completely into a suitable container.

• When oil has drained, install and lighten drain plug.

• Remove oil dipstick and fill crankcase with the recom­

mended oil (See Page 8). The engine crankcase can hold
about 1 quart (950ml). DO NOT FILL ABOVE “FULL"
MARK.

CHANGE OIL FILTER

Replace the engine oil filter after the first 8 hours of

operation, every 50 operating hours thereafter.
• Turn oil filter counterclockwise to remove (Figure 4).

• Coat gasket of new filter with engine oil.

• Turn new filter clockwise until its gasket contacts lightly

with the filter adapter. Then tighten with an additional 3/4
to one turn by hand.

• Run engine and check for leaks.

NOTE: Check the oil level and fill to FULL mark on
dipstick after checking for leaks. The filter will retain
some oil.

ENGINE AIR CLEANER

Paper Filter: Once every 25 operating hours or once
each year (whichever comes first), clean or replace

the paper filter (Figure 5). Follow these steps:
• Remove air cleaner cover, then remove paper filter.

• Clean air filter by gently tapping it on a solid surface. If

the filter is too dirty, replace it with a new one. Dispose of
the old filter properly.

• Clean air cleaner cover then insert new paper filter into

cover and assemble them to the base of the air cleaner.

Figure 5 — Engine Air Cleaner Assembly

PAPER
FILTER

— 9 —

Advertising