LOCATION AND SUPPORT

GENERATOR LOCATION

The most desirable location for the generator set is

between the vehicle's main frame members However,

this is seldom possible. Most units must be installed

on the side of the vehicle and are difficult to reinforce.

Many

recreational

vehicles

have

been

factory

equipped with an area for the generator set. Some

vehicles may even have a generator compartment,
provided by the vehicle manufacturer.

Plan the generator location based on the following:

• The generator set must be installed on a framework that

is part of the recreational vehicle, as outlined in the para­

graph entitled “Generator Support.”

• The location must provide an access opening that is iarge

enough to permit generator removal (unless the genera­

tor is to be removed from underneath the supporting

framework.

• The location must provide easy access to frequently ser­

viced components, such as filters, oii drains, spark plugs
and other common maintenance parts.

• The location must provide sufficient room to allow mini­

mum clearance of at least 1 inch between all sides and 1-

1/2 inches on top of the generator. If sound insulation is

to be used on compartment walls and ceiling, the mini­

mum recommended applies to the space between the

generator and such insulation.

• The location must provide adequate cooling and ventilat­

ing air flow for the generator without a great deal of work

and expense.

GENERATOR SUPPORT

The generator must be securely attached to a metal
framework that has been made part of the vehicle
frame structure by bolting or welding. The metal
framework on which the generator will rest and which
will restrain the generator set should consist of at

least two horizontal beams. These beams should con­
sist of (a) 1-1/2 inch square, 11 gauge steel tubing
OR (b) 1-1/2 inch, 11 gauge angle iron. A typical sup­
porting frame with horizontal support tubing, is shown
in Figure 3.

The generator can be installed so that it sits on top of
the horizontal support tubing, if the vehicle design

permits. Another method is to suspend the generator
below the horizontal support tubing by means of suit­
able, structurally sound metal framework. The follow­
ing general rules apply:

• Vehicle construction MUST be capable of supporting the

weight of the generator.

• Whether the generator is mounted above the horizontai

support tubing or suspended below the tubing, the sup­
porting frame used must be structurally sound.

If the generator cannot be bolted directly to the support­
ing frame or support tubing, consider using additional

tubing, angle brackets or other supports to give the sup­
porting frame sufficient strength.

Figure 3 — Typical Horizontal Support Frame

SUSPENDED MOUNTING

If you are going to suspend the generator below the
horizontal support tubing, the suspension method you

use with the vehicle frame members must have the
following: (a) be able to support the weight of the gen­
erator; and (b) provide sufficient restraint for the gen­
erator. One typical suspended mounting system is
shown in Figure 4. The location of a suspended

mounting system must be carefully planned, keeping

the following general rules in mind:

• Protect the generator against road splash and debris.

Baffles or splash guards may be required to protect cer­

tain areas of the generator. To make sure the generator is
adequately protected, road test the installation through
mud, water and slush.

Figure 4 — Typical Suspended Mounting System

• The installer must make certain the selected location will

permit adequate cooling and ventilating air flow to be

supplied.

5

Advertising