Specifications, General maintenance recommendations, Engine maintenance – Generac 1019-3 User Manual

Page 14: Generator maintenance, Battery maintenance, Caution

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

fortiibk Prodicta

7500EXL Extended Life Generator

SPECIFICATIONS

Maximum Surge Watts.............................. 13,500 watts

Continuous Wattage Capacity ..................7,500 watts

Power Factx>r ............................................................ 1.0

Rated Maximum Continuous AC Load Current:

At 120 Volu.................................................62.5 Amps

At 240 Volu.................................................31.2 Amps

Phase .................................................................. I-phase

Rated Frequency ........................... .............. .............. .............. .............. .60 Hertz

Fuel Tanic Capacity......... .................... ... 7 U.S. gallons

ShippingWeight ............ .................. ................ 240 bs.

GENERAL MAINTENANCE

RECOMMENDATIONS

The Owner/Operator is responsible for making sure that
all periodic maintenance tasks are completed on a timely

basis; that all discrepancies are corrected; and that the unit
is kept clean and proper y stored. NEVER operate a
damaged or defective generator.

Engine Maintenance

See engine owner’s manual for instructions.

Avoid prolonged or repeated skin contact with used

motor oil.

Generator Maintenance

Used wQisr |oih has

shown; ts; cause cancer in

certain: jaboTatory animals.;;;;;;;;;;;;;;;;;;;;;;;;
ThoTOugh^imshlexposed areas: with soap and watch 111

KEEP OUT OF REACH OF CHILDREN. DON’T
POLLUTE. CONSERVE RESOURCES. RETURN
USED OIL TO COLLECTION CENTERS.

Generator maintenance consists of keeping the unit clean
and dry. Operate and stor^ the unit in a clean dry
environment where it will not be exposed to excessive
dust, dirt, moisture or any corrosive vapors. Cooling air
slots in the generator must not become clogged with snow,
leaves or any other foreign material.

NOTE; DO NOT use a prden hose to clean generator.

Water can entsr engine fue system and cause prob ems. In
addition, if water enters generator through coo ing air slots,
some of the water will be refined in voids and cracks of
the rotor and statx>r winding insulation.Watsr and dirt
buildup on the generator interna windings will eventua ly
decrease the insulation resistance of these windings.

Battery Maintenance

Other than float charging, described elsewhere, no
maintenance is required for the battery. Keep the battery
and terminals clean and dry.

IMPORTANT; Battery charging should be performed in a

dry location, such as inside a garage.

To Clean the Generator_______________

• Use a damp cbth to wipe exterior surfaces clean.

CAUTION

Improper ti'eatment of genei'ator can damage it and

shoi'ten its life.

DO; NOT expose ;gehera1fer:tQ:exce33lye moiscure, dust, dire,:
pr;c;prresiye;yappr3,;;;;;;;;;;;;;;;;;;;;;;;;;......................

DO:NOT:ihsert:ariy:dbjectS:thrQUgh:COOling:Slot3::::::::::::::

Use a soft bristle brush to loosen caked on dirt or oi

Use a vacuum cleaner to pick up loose dirt.

Use low pressure air (not to exceed 25 psi) to blow

away dirt. Inspect coo ing air slots and opening on
generator.These openings must be kept clean and

unobstructed.

Advertising