STORAGE

The generator should be started at least once every seven

da)ra and a lowed to run at least 30 minutss. If this cannot
be done and you must store the unit for more than
30 days, use the following guidelines to prepare it for
storage.

Generator Storage__________________

• C ean the generator as outlined in “To Clean the

Generator.”

• Check that cooling air slots and openings on generator

are open and unobstructed.

Engine Storage

WARNING

Storage covers can be flamntnble.

; DO NOT; place a stora^ cover; over a; hoi gororaton ;;
: LoC equipment cool for a sufficient time before placing the
: cover on the equipment:::::::::::::::::::::::::::::::::

See engine owner’s manua for instructions.

Other Storage Tips

To prevent gum fram forming in fue system or on

essential carburetor parts, add fuel stabilizer into fuel

Шпк and fil with fresh fue, Run the unit for several

minutes to circu ate the additive through the carburetor.

The unit and fue can then be stored for up to
24 months. Fue s^bilizer can be purchased loca ly,

DO NOT store fuel from one season to another unless
it has been treated as described above.

Replace fuel conuiner if it surts t» rust. Rust and/or dirt
in fuel can cause problems if it‘s used with this unit.

Store unit in a clean and dry area.

TROUBLESHOOTING

РтоЫепп

Cause

Correction

No ДС output is available,

but engine is running.............

: One :of thé:CÌrCUÌt:brèaterS:ÌS: Орёп;....1. Reset dixutt breaker.

2, : : : Faultin generator"............................... 2, Contact Generile service facility.

3. : : : РООГ: СОППесИОП :ЬГ: defective cor d set.: : :

;3.;;;;Check; and; repair.....................

4, Connected; device ;is; bad.

4, Connect another; device; diat;is ; in

.......good condit on. ...........................

Engine runs good at: no^:

I load but

■ down”

iwhién; ioadis connected.

I , Short circu Ч in a co'^ected toad,

2. Ge-erator’s overoaded.

3, Shorted generator c rcuit.

; Diisconh:ect;s;horted; electrical ;|cKid,

iSeel-'Dlbn-tOverload Generator".;

Contact Ge~erac service fecility.

Engine will not starts or

starts and runs njugh.

1; Fuel iValve; is; in the; “Off'; position.;

2.;;; Failed; battery.

;Turn; ;fuel та1Уе to ‘'On" position.

Rep ace battery.

Engine shuts down during

operation, ...............................

Out ;of gasoline,;

Fill fuel;tank.

Engine lacks power.

Load ;ls;too; high,;

See "Don’t O^rload Generator".