Th er m os ca n, English – Braun ThermoScan IRT 6510 User Manual

Page 6

Advertising
background image

8

9

English

Changing the temperature scale

If you wish to change the temperature scale of your thermometer:

Make sure the thermometer is turned off.

Press and hold down the Power button

. After about 3 seconds

the display will show this sequence: ° C / SET / ° F / SET ...

Release the Power button

when the desired temperature scale is shown.

There will be a short beep to confirm the new setting, then the thermometer
is turned off automatically.

Replacing the batteries

The thermometer is supplied with two 1.5 V type AA (LR 06) batteries.
For best performance, we recommend Duracell

®

alkaline batteries.

Insert new batteries when the battery symbol appears on the display.

Open the battery compartment. Remove the batteries and replace with new
batteries, making sure the poles are in the right direction.

Snap battery door into place.

Th

er

m

oS

ca

n

15 sec

15 sec

This thermometer includes a convenient night light
to illuminate the display in a dim environment.
The light will turn on when you press any button. It
will stay on until the thermometer is inactive for up
to 15 seconds even after temperature is taken.

The probe tip is the most delicate part of the thermometer. It must be
clean and intact to ensure accurate readings. If the thermometer is ever
accidentally used without a lens filter, clean the probe tip as follows:
Very gently wipe the surface with a cotton swab or soft cloth moistened
with alcohol. After the alcohol has completely dried out, you can put a new
lens filter on and take a temperature measurement.
If the probe tip is damaged, please contact Consumer Relations.
Use a soft, dry cloth to clean the thermometer display and exterior. Do not use abrasive cleaners.
Never submerge this thermometer in water or any other liquid. Store thermometer and lens filters
in a dry location free from dust and contamination and away from direct sunlight.
Additional lens filters (LF 40) are available at most stores carrying Braun ThermoScan.

1

2

3

To protect the environment, dispose of the product and empty batteries at
your retail store or at appropriate collection sites according to national or
local regulations.

Calibration

The thermometer is initially calibrated at the time of manufacture. If this thermometer is used according to
the use instructions, periodic re-adjustment is not required. If at any time you question the accuracy of
temperature measurements, please contact Consumer Relations.

Manufacturing date is given by the LOT number located inside the battery compartment. The first three (3)
digits after LOT represent the Julian date that the product was manufactured and the next two (2) digits
represent the last two numbers of the calendar year the product was manufactured. The last identifiers are
the letters that represent the manufacturer.

An example: LOT 11614KTC, this product has been manufactured on the 116th day of the year 2014.

Errors and troubleshooting

Situation

No lens filter is attached.

The thermometer probe was not
positioned securely in the ear.
An accurate measurement
was not possible.

POS = position error

Ambient temperature is not within
the allowed operating range
(50 – 104 °F or 10 – 40 °C ).

Temperature taken is not within
typical human temperature range
(93.2 – 108 °F or 34 – 42.2 °C).

HI = too high

LO = too low

System error – self-check display flashes
continuously and will not be followed by
the ready beep and the ready symbol.

If error persists,

If error still persists,

Battery is low, but thermometer will
still operate correctly.

Battery is too low to take correct
temperature measurement.

Error Message

Solution

Attach new, clean lens filter.

Take care that the positioning of the
probe is correct and remains stable.

Replace lens filter and reposition.
Press Start button to begin a new
measurement.

Allow the thermometer to remain for
30 minutes in a room where the
temperature is between 50 and 104 °F
or 10 and 40 °C.

Make sure the probe tip and lens are clean
and a new, clean lens filter is attached.
Make sure the thermometer is properly
inserted. Then, take a new temperature.

Wait 1 minute until the thermometer turns
off automatically, then turn on again.

... reset the thermometer by removing the
batteries and putting them back in.

… please contact Customer Service.

Insert new batteries.

Insert new batteries.

3

1
2

A

vailable only in

IR

T 6510

Care and cleaning

Night light feature

Advertising
This manual is related to the following products: