Checkout menus, Service menus, Setup -- utility saver – Carrier Infinity SYSTXCCUID01- B  User Manual

Page 12: Checkout -- furnace or gas pac, Checkout -- electric heat, Checkout -- heat pump heating, Checkout -- heat pump cooling or ac cooling, Checkout -- humidifier, Checkout -- ventilator, Checkout -- system access module (sam)

Advertising
background image

12

SYSTEM MAINTENANCE

< BACK

REMIND OWNER OF
MAINTENANCE EVERY:

12 MONTHS

% USED:

50%

RESET >

A07033

Fig. 30 -- System Maintenance

Pressing the right side button will reset the timer. Pop--up

confirmation will be shown.

Setup -- Utility Saver

Cooling/Heat Pump Heating: (Hybrid Heat & Hydronic Heat
Only)

S

Turn off, Low Stage

Utility Saver is used to force the equipment to a lower stage (low

or off) when activated by the utility company, typically during

peak load times.
This setup is available only if the equipment has a utility saver

input (refer to equipment Installation Instructions.) This setup
controls the response of the equipment when the utility saver input

is active.
The choices include:

S

Turn Off , (equipment turns off)

S

Low Stage (available if the AC/heat pump is a 2--stage model,
runs low speed only)

CHECKOUT MENUS

The Checkout menu will show the equipment installed in the

system. A sample checkout menu is shown in Fig. 31.

CHECKOUT

FURNACE

HEAT PUMP HEATING

HEAT PUMP COOLING

HUMIDIFIER

VENTILATOR

BACK SELECT

A03204

Fig. 31 -- Checkout Menu

Checkout -- Furnace or Gas PAC

Make sure the furnace is properly installed before continuing.

S

LOW HEAT RUNTIME: 5 min.

S

HIGH HEAT RUNTIME: 5 min.

This menu item allows the furnace to be exercised. First, a low heat

runtime and high heat runtime are selected. Range = 5 -- 120 min.
If only the low heat is to be exercised:
The furnace will execute its ignition start--up sequence. This

sequence will be displayed on the Infinity Control screen. After the
gas valve and blower motor turn on, the screen will automatically

change to “FURNACE CHECK” and show the current operating
status of the furnace.

Checkout -- Electric Heat

S

ELECTRIC HEAT RUNTIME: 5 min., Default time = 5 min.,
Range = 0 -- 120 min.

If you have a fan coil with electric heaters, this menu item will

allow the heaters to be exercised.

With self--identifying electric heaters, three stages of electric heat
are available to be exercised in any combination. Non--identifying

heaters will only provide one stage of heat.
Enter the run time (in minutes) of each stage of heat to be exercised

then press START (right--side button). The display will change to

show the fan coil’s operating status.

Checkout -- Heat Pump Heating

S

HIGH HEAT RUNTIME: 5 min.

S

LOW HEAT RUNTIME: 5 min.

S

DEFROST: NO

The heat pump heating mode can be exercised with this menu

option. With a 2--stage heat pump, a low heat runtime and a high

heat runtime are independently selectable to exercise. A defrost
cycle is also selectable. Default time = Fixed 5 min. minimum,

range = 5 -- 120 min.
NOTE:

Airflows during Checkout modes are fixed to the

Efficiency setting and are independent of other airflow settings. To
view airflows for normal heat pump heating mode, exit the
Checkout screen and apply a heating demand to the system.

Checkout -- Heat Pump Cooling or AC Cooling

S

HIGH COOL RUNTIME: 5 min.

S

LOW COOL RUNTIME: 5 min.

The heat pump cooling mode (or AC cooling mode) can be
exercised with this menu option. With a 2--stage heat pump or AC

unit, a low cool runtime and a high cool runtime are independently

selectable to exercise. The display will change to show the heat
pump or AC operating status.
Default time = Fixed 5 min. minimum, range = 5 -- 120 min.
NOTE:

Airflows during Checkout modes are fixed to the

Efficiency setting and are independent of other airflow settings. To
view airflows for normal heat pump heating mode, exit the
Checkout screen and apply a heating demand to the system.

Checkout -- Humidifier

S

OFF

S

ON

The humidifier can be exercised On and Off with this menu option.

Checkout -- Ventilator

Speed:

S

OFF

S

LOW

S

HIGH

The ventilator can be exercised through all of its operating speeds
with this menu option.

Checkout -- System Access Module (SAM)

See System Access Module Installation Instructions for full details.

SERVICE MENUS

The Service Info menu will only show the equipment installed in
the system. Below is a sample using a furnace and a heat pump

(Hybrid Heat). A sample service menu is shown in Fig. 32.

SERVICE INFO

FURNACE STATUS

HEAT PUMP STATUS

LAST 10 SYSTEM FAULTS

RUN/FAULT HISTORY

TODAY’S DATE

MODEL/SERIAL NUMBER

SERVICE PHONE NUMBER

BACK SELECT

A03205

Fig. 32 -- Service Info Menu