Ant+ sensor troubleshooting – Garmin Edge 800 User Manual

Page 21

Advertising
background image

Edge 800 Owner’s Manual

17

ANT+ Sensors

ANT+ Sensor Troubleshooting

Problem

Solution

The ANT+ sensor

will not pair with my

device.

• Stay 10 m away from other ANT+ sensors while pairing.

• Bring the device within range (3 m) of the heart rate monitor

while pairing.

• If the problem persists, replace the battery.

I have a third-party

ANT+ sensor.

Make sure that it is compatible with the Edge

(

www.garmin.com/intosports

).

The heart rate data is

inaccurate or erratic.

• Make sure that the heart rate monitor is snug against your body.

• Warm up for 5–10 minutes.

• Reapply moisture to the electrodes and contact patch. Use

water, saliva, or electrode gel.

• Wash the strap after every seven uses.

• Wear a cotton shirt or wet your shirt if suitable for your activity.

Synthetic fabrics that rub or flap against the heart rate monitor

can create static electricity that interferes with heart rate

signals.

• Move away from sources of strong electromagnetic fields and

some 2.4 GHz wireless sensors, which can interfere with your

heart rate monitor. Sources of interference may include high-

voltage power lines, electric motors, microwave ovens, 2.4 GHz

cordless phones, and wireless LAN access points.

How much should I

tighten the sensor arm

screw when installing

my GSC 10?

Garmin recommends that the torque is 1.9 to 2.4 lbf-in to ensure a

water tight seal on the GSC 10 sensor arm.