Troubleshooting guide – Hunter X-CORE User Manual

Page 29

Advertising
background image

27

problem

Causes

solutions

Seasonal Adjust seems high

• Region too low
• Water Adjustment setting too high

Decrease the value of the Water Adjustment setting. If

you minimize the Water Adjustment scale at 1 and still

require reduced seasonal adjustment, move up one

Region (from 2 to 3, for example) and start at Water

Adjustment setting 5. Solar Sync will immediately update

the Seasonal Adjust on the Controller. If it is still too high,

repeat the adjustment until the desired seasonal adjust is

showing on the controller.

Solar Sync still sending Seasonal Adjust

when Controller Bypass switch is in the

“Bypass” position

Solar Sync’s automated Seasonal

Adjustment cannot be de-activated by

the Bypass switch. The Bypass switch

only controls the Rain/Freeze shutoff

function of the Solar Sync.

After removing the Solar Sync sensor

from the controller, the seasonal adjust

value cannot be changed manually

The Solar Sync sensor needs to be

uninstalled if permanently removing

it from the controller

After removing the Solar Sync sensor from the controller,

turn the knob to Solar Sync Settings. The screen should

show dashed lines. The sensor is now uninstalled (see

page 14).

Display shows “no SS”

• Solar Sync sensor has been

disconnected from controller but

not uninstalled

• Wiring connection from Solar Sync

connection is faulty

• Check Solar Sync sensor wiring connection to controller
• Uninstall Solar Sync sensor if intent is to permanently

remove sensor from controller (see page 14)

TroUblEsHooTING GUIDE