Connecting valves and transformer – Hunter X-CORE User Manual

Page 9

Advertising
background image

7

CoNNECTING ValVEs aND TraNsformEr

Installation of the X-Core should only be done by trained personnel.
1. Route valve wires between the control valve location and controller.
2. At valves, attach a common wire to either solenoid wire on all

valves. This is most commonly a white colored wire. Attach a

separate control wire to the remaining wire of each valve. All wire

connections should be done using waterproof connectors.

3. Route the valve wires through the conduit. Attach the conduit

through the bottom right side of the controller.

4. Secure the white valve common wire to the C (Common) screw on

the terminal strip. Attach each of the individual valve control wires

to the appropriate station terminals and tighten their screws.

5. Indoor Models: route the transformer cable through the hole on

the left side of the controller and connect the wires to the two

screws marked 24VAC.

Outdoor Models: transformer wires are already connected to the

AC terminals so all that is required is to connect primary power to

the junction box (see below).

NoTE: X-Core outdoor models are water and
weather resistant. Connecting the outdoor X-Core
to primary AC power should only be done by a
licensed electrician following all local codes. Improper
installation could result in shock or fire hazard.

BAT

High Voltage Wiring (Outdoor Model only)

1. Route AC power cable and conduit through the ½" (13 mm)

conduit opening on the left side bottom of the cabinet.

2. Connect one wire to each of the two wires inside the junction

box. The ground wire should be connected to the green wire.

Wire nuts are provided to make these connections.

note: For –e models only: Connect the wires to the AC

terminal block inside the junction box. AC supply wires must

be 14 AWG (1.85 mm) or larger with appropriate circuit

breaker for the wire size. A switch or circuit-breaker shall be

included in the building installation (in close proximity to the

controller, within easy reach of the operator) and marked as

the disconnecting device for the equipment.

3. Replace the junction box cover.

Connect the two transformer

wires to the two aC Terminals

Valve Common Wire

Valve 4

Valve 3

Valve 2

Valve 1

Valve

Wires