Defiant clearance chart – Vermont Casting 1945 User Manual

Page 13

Advertising
background image

13

Defiant Woodburning Stove

30001693

Defiant Clearance Chart

for use with either a 6” or 8” chimney connection

Stove Clearance

Stove Installed

Parallel to Wall

Unprotected Surfaces

Protected Surfaces

Side

Rear

Corners Side Rear Corners

No stove

heat shields

Chimney Connector Clearance

Unprotected Vertical Surfaces Protected Vertical Surfaces

Single-wall connector

Single-wall connector;

rear heat shield on

stove only

Clearance to Combustibles in Front of Stove

48” (1220 mm)

30” (760 mm)

25” (635 mm)

18” (460 mm)

14” (355 mm)

All Installations

Stove Installed
Parallel to Wall

Stove

in

Corner

Stove

in

Corner

Stove, top exit with rear

heat shield, no connector

heat shields

Single-wall connector

with shields, and rear heat

shield on stove

Double-wall chimney con-

nector

(A) 24”

(B) 33”

(C) 23”

(D) 14”

(E) 28”

(F) 18”

(610 mm)

(840 mm)

(585 mm)

(355 mm)

(710 mm)

(460 mm)

(M) 24”

(N) 17”

(O) 17”

(P) 14”

(Q) 17”

(R) 12”

(610 mm)

(430 mm)

(430 mm)

(355 mm)

(430 mm)

(305 mm)

(G) 24”

(H) 21”

(I) 17”

(J) 14”

(K) 17”

(L) 12”

(610 mm)

(533 mm)

(430 mm)

(355 mm)

(430 mm)

(305 mm)

Stove, top exit with rear

heat shield, and double-

wall chimney connector*

Stove, top exit with rear

heat shield, and heat

shields on connector

Unprotected or Protected Ceiling Surfaces

24” (610 mm)

Single-wall connector

14” (355 mm)

14” (355 mm)

14” (355 mm)

12” (305 mm)

* Using a listed double wall oval to round connector.

Stove, rear exit with rear

heat shield only

(Y) 27”

(Z) 24”

N/A

(AA) 17”

(BB) 20”

N/A

(686 mm)

(610 mm)

(430 mm)

(508 mm)

(S) 24”

(T) 17”

(U) 17”

(V) 14”

(W) 15”

(X) 12”

(610 mm)

(430 mm)

(430 mm)

(355 mm)

(380 mm)

(305 mm)

Advertising