Defiant Woodburning Stove

30001693

48"

(1220mm)

48"

(1220mm)

48"

(1220mm)

ST498

Defiant

Wall shield B

11/00

Fig. 17 Parallel installation with rear wall pass-through, two
wall shields. Reduced clearances to both rear and side walls.
Wall shields may meet at corner if desired. Wall pass-through
must comply with codes.
Refer to “Special Installations.”

ST498

48"

(1220mm)

48"

(1220mm)

48"

(1220mm)

48"

(1220mm)

ST499

Defiant

Wall Shield C

11/00

ST499

Fig. 18 Corner installation, vertical chimney connector, two
wall shields. Reduced side clearances. Wall shield MUST
meet at corner.

Stove Heat Shields

The Vermont Castings Defiant Rear Heat Shield, shown
below, is one way to reduce the clearance to the rear
wall. The rear heat shield can be installed in any set-
ting. However, since the chimney connector also radi-
ates heat toward the wall, you must use a chimney con-
nector shield whenever you use the rear heat shield.
Clearance reductions with the rear heat shield apply
only to the wall to the rear in parallel installations. Nei-
ther the side clearance requirement nor the clearance
requirement in corner installations may be reduced.

48"

(1220mm)

48"

(1220mm)

48"

(1220mm)

48"

(1220mm)

ST497

Defiant

wall shield A

11/00

Fig. 16 Parallel installation, vertical chimney connector, two
wall shields. Reduced clearances for both rear and side walls.
Wall shields may meet at corner if desired. Shielding for con-
nector is centered behind connector.

ST497

Fig. 19 Defiant rear heat shield with flue collar heat shield for
top exit configuration.

Flue Collar Heat

Shield

Rear Heat

Shield

Spacers

Truss Head

Phillips Screws