Vermont Casting 1945 User Manual

Page 16

Advertising
background image

16

Defiant Woodburning Stove

30001693

Distance from the Center of the Flue Collar to the Wall

The information on this page is helpful in planning stove placement, particularly in those installations with
chimneys that pass through the ceiling. However, this is not a clearance chart. Final stove clearances must
adhere to the guidelines in the clearance chart on Page 12.

Note that rear dimensions differ for installations with 6” or 8” chimney connectors.

Defiant With Rear Heat Shield only

Unprotected Surfaces

Protected Surfaces

Parallel Installations

Corner

Installations

Corner

Installations

Parallel Installations

Defiant With Rear Heat Shield and Shielded Connector:

Defiant With Rear Heat Shield and Double-wall Connector:

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

39¹⁄₂” (1003mm)

6” chimney:

28” (710 mm)

29¹⁄₂” (710 mm)

6” chimney:

25” (635 mm)

27” (685 mm)

21” (535 mm)

8” chimney:

8” chimney:

28” (710 mm)

22” (560 mm)

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

39¹⁄₂” (1003mm)

6” chimney:

28” (710 mm)

29¹⁄₂” (710 mm)

6” chimney:

25” (635 mm)

17” (432 mm)

17” (432 mm)

8” chimney:

8” chimney:

18” (457 mm)

18” (457 mm)

Side (A)

Rear (B)

Corner (C)

Side (D)

Rear (E)

Corner (F)

39¹⁄₂” (1003mm)

6” chimney:

28” (710 mm)

29¹⁄₂” (710 mm)

6” chimney:

25” (635 mm)

17” (432 mm)

15” (381 mm)

8” chimney:

8” chimney:

18” (457 mm)

16” (406 mm)

ST511

Intrepid

flue centerline

Diagrams

11/16/00

*

A

B

C

*

D

E

F

* This distance, from the center of the flue collar to the front edge of the hearth, is the same for all installations on this
page: 34” (865 mm) in the United States and 36” (914 mm) in Canada.