Figure 1, Activating and installing the battery, Large tab – Bolens TMO-33920A User Manual

Page 7: Figure 2, Note

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

Screwdriver

Manifold

on Battery

Clear Plastic

Drain Tube

\

FIGURE 1.

ACTIVATING AND INSTALLING THE BATTERY

Fill Caps

Large Tab

Filling

Adapter

FIGURE 2.

Ai

DANGER

Battery contains sulfuric acid. Refer to warning on page
6. Antidote:

EXTERNAL—Flush with water,

INTERNAL—Drink large quantities of water or milk.

Follow with milk of magnesia, beaten egg or vegetable

oil.

Seek prompt medical attention. EYES: Flush with

cool water for at least 15 minutes, then seek immediate
medical attention.

Since batteries produce explosive gases, keep all
lighted materials (cigarettes, lighters, matches, etc.)
away. Be sure to charge battery only in well-ventilated
areas.

KEEP BATTERIES

OUT OF THE REACH OF CHILDREN!

1

.

4.

5.

6

.

Upon opening the battery pack, you should receive

acid pack, battery, drain tube, filling adapter and

hardware.

AC

WARNING

2

.

3.

7.

8

.

9.

BATTERIES

CONTAIN

SULFURIC

ACID

AND

MAY

CONTAIN

EXPLO­

SIVE

GASES

(when

electrolyte

has

been added).

Place the battery on table or workbench to be filled.

Place one end of clear plastic drain tube on

-manifold of battery. See figure 1.

NOTE

Some

batteries

may

already

have

the

drain

tube

installed,

in

which

case it may be necessary to snip off
the sealed end.

Remove the six fill caps from the top of the bat­

tery with a screwdriver. Care should be taken not
to damage the fill caps. See figure 1.

Lay acid package down, with “push in” facing up.
Using thumb, push in small perforated tab at dot

on front of package. Tear down large tab to solid

line, exposing hose.

Do not use any sharp object

to open acid package.

Pull out hose from package and hold upright.
Squeeze hose forcing all acid back into package.

Cut off tip of hose and insert filling adapter. See

'figure 2.

Fill each cell to upper level marked on front of bat­

tery. Replace fill caps on battery. See figure 2.

Allow battery to sit for 20 to 30 minutes. Add addi­
tional acid, if necessary, to bring it up to the proper

level.

The battery can be charged after the 20 minutes
sitting period. SLOW CHARGE THE BATTERY
(DO NOT FAST CHARGE) at a maximum bench

rate of 1.4 amperes until the specific gravity
reading is 1.260-1.280. Charge for a minimum of

2 hours and a maximum of 8 hours.

NOTE

Charging rate after battery has been
put into operation: The battery is to
be charged for a period of 14-16
hours.

NO

LONGER

THAN

30

HOURS.
After battery has been in service,

add only distilled water. Do not add
acid.