Aiphone TC-MF User Manual

Two station intercom, Alphone, Operation

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

^ AlPHONE

832870 TC-MB-l-0986 ®

TWO STATION INTERCOM

Models: TC-MB (Set)

TC-MF (Master station)

TC-MB (SET)

(3-7/16":

- INSTRUCTIONS -

¡ 3 - 5 / 1 6 " )

ROOM STATION

DOOR STATION

TC-MF

IB-DB

(

OPERATION ^

Door station calling:

Momentarily depress call button. Talk and listen hands free

to master. Do not push call switch during conversation.

Room station receiving:

Pick up the handset and talk just as on a standard telephone.

( INSTALLATION }

* Connect terminal #1 on back of room station to terminal

#1 on door station. Then connect terminal #2 on room

station to terminal #2 on door station. MAKE SURE

YOUR WIRING IS CORRECT. Incorrect wiring will

not allow call tone or voice communication.

* Insert four 1.5V “C” batteries (not included) in battery

compartment. + and — positioning of battery terminals

is clearly indicated in the battery compartment.

Simultaneous conversation.

Electronic tone call signal with volume control.

Long battery life due to low current requirement.

LED indicator for easy checking of battery life.

Power source: DC 6 volt. Four

Wi

volt “C” batteries

(room station incorporates battery compartment) or

PS—6D power supply.

Wiring and communication range: Single pair of wires —

select the proper wire gauge to meet your requirements

from the chart below.

Diameter of wire

0.65mm

0.8mm

20AWG

22AWG

Distance

150m

230m

750'

500'

CALL VOLUME CONTROL

CALL BUTTON

PS-6D
POWER SUPPLY

*Power supply is not required if

master is powered by batteries.

IB-DB BACK VIEW