Assembling VY-10U (1 ~ 3) panels to VY-EM

VY-5EM or VY-10EM with VY-10U panel(s), are
made up for 15 to max. 40-call entrance panel.

Back box dimensions

VY station

High

Wide

Deep

VY-5EM, VY-10EM

250 mm

10 feet

VY-10EM + 1 VY-10U

20-call

240 mm

390 mm

16 feet

62 mm

VY-10EM-t-2VY-10U

30-call

10 feet

530 mm

21 feet

3 feet

VY-10EM-h3VY-10U

40-call

670 mm

27 feet

1. Loosen screws (7) on back of VY-5/1 OEM chassis.

2. Attach new junction bar (2) VYK-A20 ~ 40, aligning

on the ditch.

Fasten all screws, on VYK-A plate to unite.

3. On back boxes, before assembly, knock out a hole

on each facing side. Attach VY-10U box to VY-EM's
with 2 screws top and bottom.

4. Detach panel frames, using special screwdriver.
5. Loosen panel-fixing screws ( 6 - 1 0 ) and disconnect

VY-EMA/Y-IOU's to separate from chassis.

6. Mount the chassis (assembled) to back box.
7. Reconnect and mount VY-EM/VY-10U panels on

the chassis.

1 Loosen

Ditch

__

Ditch

Junction

bar

VY-10EM
back view

VYK-A20

^ ii ii ii

VYK-A20, adjustable

4. Detach