TECHNICAL PRECAUTIONS ----------------------------------------------------------------------

Temperature:

MK-1MD(/A) is rated to operate between temperatures 0"C ~ 40°C (+32‘F ~ +104T),

It takes approx, one second for system to recycle.
Image may vary when the Key-mark button is held down to activate door strike. This is not a malfunction.
MK-1 MD(/A) monitor can work with MY Series door components:

MY-DS, MYW-CA

(w/MY-CA inside) and

MYW-BA

long-distance adaptor.

Image through overhead MYW-CA may vary, but it is not a malfunction.
Do not operate MONITOR button and plug in at the same time. It will create a continuous high-pitched tone, and can be reset by momentarily
unplugging power supply.

Cleaning:

Clean MK-1MD(/A) with a soft cloth dampened with neutral household cleanser. Do not use any abrasive cleaner or cloth.

SPECIFICATIONS

Power source:
Power supply:

Image viewing area;

When camera is in horizontal position;
When camera is upwardly adjusted;

Communication:

MK-DS(/A) camera unit:
MK-1MD(/A) monitor:
Scanning lines:
Minimum illumination;
Door release contact capacity:
Wiring;
Wiring distance;

Dimensions & weight:

MK-1MD(/A): DC 18V, 0.8A. 0.04A (standby).
PS-18YC/A, AC 120V, 50/60HZ.
PS-18YE, AC 220-240V, 50/60HZ.,
each with secondary output: DC 18V, 1.2A.

70cm V

X

100cm H (2’3” V x 3’3” H)

75cmV

X

lOOcmH (2'5” V x 3’3” H)

Call-in: Image is on 30 sec.
Communication: 2-1/2 min. timed.

Extend with MONITOR button.

Common talk between rooms (hang up either handset)
CCD camera with infrared LEDs.
4 inch direct view flat CRT
525 lines.
Less than 1 Lux at 50cm, 20” distance.
AC 12V, 0.4A (dry closure contact EL, EL).
2 wires parallel, non-polarized (Aiphone #841802 in USA).

MK-1MD(/A) to MK-DS(/A);

0.65mm ji

I.OmmjS

50m

100m

22AWG

18AWG

165’

330’

Models H

W

D (mm)

Weight (approx.)

MK-DS(/A) 130

98

37.5

230g

MK-1MD(/A) on HD 210

186

78

1,130g

MK-1SD(/A) 210

100

74

415g

H

W

D

Weight (approx.)

5-1/8”

3-7/8”

1-1/2”

0.51 lbs.

8-1/4”

7-5/16”

3-1/16”

2.49 lbs.

8-1/4”

4”

3”

0.91 lbs.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause
harmful interference to radio communications. Flowever, there is no guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful inteference to radio or television reception, which can be determined by turning the equipment off and on,
the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna. • Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected • Increase the separation between the equipment and receiver. • Consult the dealer or an experienced radio/TV technician for

help.

-!•

-!•

•S*

-!•

-F

•F

•F
-F
•F
•F
•F
-F
-F
*F
•F

WARRANTY

Aiphone warrants its products to be free from defects of material and workmanship under normal use and service for a period of two
years after delivery to the ultimate user and will repair free of charge or replace at no charge, should it become defective upon which
examination shall disclose to be defective and under warranty. Aiphone reserves unto itself the sole right to make the final decision
whether there is a defect in materials and/or workmanship; and whether or not the product is within the warranty.
This warranty shall not apply to any Aiphone product which has been subject to misuse, neglect, accident, or to use in violation of

instructions furnished, nor extended to units which have been repaired or altered outside of the factory. This warranty does not cover
batteries or damage caused by batteries used in connection with the product.

This warranty covers bench repairs only, and any repairs must be made at the shop or place designated in writing by Aiphone.
Aiphone will not be responsible for any costs incurred involving on site service calls.

•i-

•i*
•i-

Aiphone Co., Ltd., Nagoya, Japan
Aiphone Corporation, Bellevue, WA, USA

®

COMMUNICATION SYSTEMS

AIPHONE

HOME, BUSINESS, INDUSTRY.

MK-1MD-KE) 0597B

Printed in Japan (E)

Advertising