ELECTRICAL

GANG BOX

(F) RA-B and RA-C Flush Mount Installation

RA-B/RAC
PANEL

RA-B/RA-C
UNIT

CIJ

□□□□

□□QO

□aon

SCREW lx 4)

1. Separate the RA-B/RA-C panel from the RA-B/RA-C

unit.

2. Attach the RA-B/RA-C unit to electrical box with the

supplied screws.

3. Replace the RA-B/RA-C panel to the unit with the

2 screws.

In N. America, please specify either BOWERS

703-SPL,

RACO

952,

APPLETON

3G-5075

or

equivalent.

RA-B/RA-C FLUSH-MOUNTING GUIDE

, 112 (4-7/16")

4.5 (3/16")

SCREW

(4, 3/16" DIA.)

205

(

8

-

1/16

Vj

9.2

(3/8")

, DIA.

195

(7-11/16")

240

(9-7/16"

85 (3-5/16")

^

^..........

^ BOSS '

30 (1-3/16")

62 MIN

(2-7/16")

90

(3-9/16")

rm

194

(7-5/8")

203

(

8

" )

140

(5-1 /2")

MINIMUM

MAXIMUM

1

209

(8-1/4")

RA-B/RA-C SIDE & BACK VIEW

When RA-B/RA-C are fulsh-mounted to wall, be sure that

two holes be opened for the bosses of 9.2 (3/8") diameter

and protruding 4.5 mm (3/16").

Notes on installing station units;

(1) Avoid to locate the station unit in such places as closely surrounded by wall or other things, which may interfere with

voice-switching to function properly.

(2) Keep the station unit away from the paging speakers to avoid acoustic feedback in paging mode.

(G) Connecting AC Power Line and Grounding Wire

a| RAX-8,

RAX-.16,
RAX-24

~ EARTH-GROUNDED

As shown using standard screw driver, connect AC power line to |AC INPUT) terminals, and earth-ground wire to

IFG| terminal.