V. Installation Guidelines

BE SURE TO TURN OFF RAX POWER SUPPLY BEFORE YOU OPEN THE UNIT OR

MAKE WIRING CONNECTIONS.

1.

Central Exchange Unit (CEU);

* Select location for CED that will facilitate ease of access to the unit itself.

* Plug the power supply into a clear line. Interference on the power line may cause function error.

* Select a location that:

— has low humidity.

— is free of dust.

— is vibration free.

— is free of static electricity.

— is not near flammable or chemical product.

— is not close to high voltage equipment.

— is not within a strong magnetic field.

— is not near heating or air conditioning outlets or equipment.

— does not have direct sunlight.

— does not have temperature extremes: below 0°C (+32°F) or above + 40°C (+104°F).

2.

Station;

* Each station must be home run wired to the C.E.U. individually, and must have individual station numbers.

* Follow location guidelines for the Central Exchange Unit when selecting station location.

* Avoid locations where temperature dips below —10°C (+14°F) or exceeds +60°C (+140°F).

* Select a most suitable type of station according to your communication requirements and environmental conditions.

3.

Wiring;

* Use 2 twisted pairs for each station.

* Keep twisted pair cable well apart (over 50 cm or 20") from other cables such as heavy duty power lines, telephone

lines and/or paging amplifier output line (speak line).

4.

Installation;

* In new construction install single-gang box for RA-A or RA-D stations or electrical box (see page 14) where

RA-B or RA-C stations are to be wall-mounted. The station will cover the hole, when installed.