BEFORE YOU INSTALL AND OPERATE THE EQUIPMENT

— Prohibitions and precautions —

Operation;

DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CHIME TONE
SOUNDS THROUGH THE HANDSET RECEIVER ELEMENT AND COULD CAUSE HEARING
DAMAGE.

Installation;

* DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.

When you mount lE-lAD(U) unit in place of existing bell or chime, be sure to disconnect wires
from the present transformer.

* BE SURE TO DISCONNECT WIRES FROM BELL TRANSFORMER (or POWER SUPPLY)

BEFORE YOU OPEN THE lE-lAD(U) UNIT OR MAKE WIRING CONNECTIONS.

* Avoid running the connecting wires through doors, windows or between furniture, which may pinch

and disconnect the wires.

* lE-lAD(U) equipment must be installed in as dry and dust-free environment as possible.

Maintenance;

* Clean your lE-lAD(U) equipment with a soft cloth dampened with neutral household cleanser. Never

use thinner, lacquer or benzine, etc.

* Do not splash water on the door station by hose, etc.

NEVER

NEVER

SYSTEM COMPONENTS

lE-FY

IE-1AD(U

lE-NC

lE-JA

IER-2

\

M

.!

i

y:

S

IE-DL3

EL-9S

Room station;
lE-lAD(U) ; Room master station. Wall-mount.

Door stations (one per system);
IF-DA : with brown plastic cover (surface-mount).
lE-DC ; - do - (surface-mount).
lE-NC : - do - (semi-flush mount).
lE-JA : with stainless steel cover (flush-mount).

lE-FY : with aluminum cover (flush-mount).
lE-DLl : 1-call, with brown anodized aluminum cover (surface-mount).
IE-DL2 : -do-2-call.
IE-DL3 : -do- 3-call (each with illumination lamp).

Options;
IER-2 : Call extension speaker, with volume control.
EL-9S ; Door release. AC 12V, 0.35A. Requires a separate bell transformer.

3

Notes; Your lE-lAD(U) can not work with IB/IC/ID series door stations. As to call extension, ICR-1 can be included in

lE-lAD(U) system.

INSTALLATION

[ (1) Actual terminal location;

CASE & CHASSIS INSIDE VIEW

For power supply.

Connect to door station (non-polarized).

For electric door release.

For cal! extension
(non-polarized)

(1) Remove 2 screws on back of the chassis and separate front case and chassis.
(2) As shown, take out two WHITE wires thru a hole on the chassis.
(3) Connect 2 wires to the wires from the IER-2 (non-polarized).

-