@ AIPHONE

DS-B-l-0986 fe

DOOR STATION ADAPTOR

Model:

DS-B

DS-B DOOR STATION ADAPTOR IS DESIGNED FOR USE WITH TS-K SPEAKER-PHONE

INTERCOM SYSTEM.

- INSTRUCTIONS -

* Power source

CALL

TONE

SWITCH

May be extended from PS-12S (PS-

12C in North America) of TS-K sys­

tem.

* Current consumption; 50 mA maximum.

* Wiring: 5 wires between DS-B and TS-K master

(polarized)

2 wires between DS-B and door station

(non-polarized)

* Wiring distance; Select the proper wire gauge to

meet your requirements from the

chart below;

* PLEASE SELECT THE MOST SUITABLE DOOR

STATION FOR YOUR APPLICATION;

MAXIMUM COM­

MUNICATION

DISTANCE FROM

TS-K TO DOOR

STATION

DIAMETER 0.5 mm 0.65 mm 0.8 mm

DISTANCE

90 m

150 m

230 m

AWG

24 AWG 22 AWG 20 AWG

DISTANCE

300'

500'

750'

IC-DC

IC-NA

IC-RA

IC-KA

I

IC-JA

IC-FY

(

WALL MOUNTING

Attach the mounting bracket to gang box or wall

with the supplied screws. Insert the prongs of the bracket

into the holes of the body and pull the body downward.

DS-B

M O U N T I N G
B R A C K E T

-- -

'

83.5

.(

3

-

5

/

16

”) ■

WALL

l|

CALL TONE SWITCH )

The call tone (tremolo sound) from door can be set

either fast or slow by using the switch provided. TS-K

speaker-phones can identify which door station called.

c TO PREVENT ELECTRIC SHOC^

DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.

BE SURE TO REMOVE PLUG OF PS-12S OR PS-12A (OR PS-12C) FROM POWER OUTLET BEFORE YOU

OPEN THE UNIT OR MAKE WIRING CONNECTIONS.

Do not pinch connecting wires in windows, doors or desks.

DS-B must be installed in as dry and dust-free environment as possible.

ACTUAL TERMINAL LOCATION

E

EE

. . for connecting to number terminal of TS-K

master

. . for connecting to terminal of TS-K master

. . for connecting to ¡Ed| terminal of TS-K master

for connecting E S terminals of PS-12S or

' PS-12A (or PS-12C) power supply adaptor

. . for connecting door station (non-polarized)