Pantilt ie-8md with 2 video-monitors – Aiphone My-Cu User Manual
Page 6
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

PanTilt IE-8MD with 2 video-monitors
Single PS-18C or PS-18D powers both lE-
8MD and MY-CU, locating an MYH-CU on
75m, 245’.
One to 5 IE-8HD with 4-wire cable, station-to-
station. PanTilt MY-CU monitor with 6-wire cable
separately sheathed. PanTilt door requires 2
parallel wires, connected directly to MY-CU
monitor.
■k
Connecting jumpers
In single PS-18C(D) sourced system, a
D1 - D1 jumper is only required. Add another
D2 - D2 when IF-DA is installed.
Install a third jumper on E - E1, when a
separate audio & video power source is used.
STATION #
1
IE-8MD &
4
IE-3HD &
I Wiring distance
MY-CU to PanTilt door
Diameter
0.65mm
0.8mm
1.0mm
Distance
50m
70m
100m
AWG
22AWG
20AWQ
18AWG
Distance
165’
230'
330’
MY-CU to farhest MYH-CU (2 monitors)
Diameter
0.65mm
0.8mm
1.0mm
Distance
35 m
50m
75m
AWG
22AWG
20AWG
18AWG
Distance
115’
160’
250’
IE-8MD to audio door station
Diameter
0.65mm
0.8mm
1,0mm
Distance
150m
230m
360m
AWG
22AWG
20AWG
18AWG
Distance
500’
750’
1,180’
Two farthest stations (any pair)
Diameter
0.65mm
0.8mm
1.0mm
Distance
75m
120m
190m
AWG
22AWG
20AWG
18AWG
Distance
250’
380’
630’
MY-CU/1E-8MD to power supply PS-18D(C)
Diameter
1.0mm
AWG
18AWG
Distance
5m
Distance
16’
-
6
-