Pantilt ie-8md with 2 video-monitors – Aiphone My-Cu User Manual

Page 6

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

Advertising
background image

PanTilt IE-8MD with 2 video-monitors

Single PS-18C or PS-18D powers both lE-
8MD and MY-CU, locating an MYH-CU on
75m, 245’.

One to 5 IE-8HD with 4-wire cable, station-to-
station. PanTilt MY-CU monitor with 6-wire cable
separately sheathed. PanTilt door requires 2
parallel wires, connected directly to MY-CU
monitor.

■k

Connecting jumpers

In single PS-18C(D) sourced system, a
D1 - D1 jumper is only required. Add another
D2 - D2 when IF-DA is installed.
Install a third jumper on E - E1, when a

separate audio & video power source is used.

STATION #

1

IE-8MD &

4

IE-3HD &

I Wiring distance

MY-CU to PanTilt door

Diameter

0.65mm

0.8mm

1.0mm

Distance

50m

70m

100m

AWG

22AWG

20AWQ

18AWG

Distance

165’

230'

330’

MY-CU to farhest MYH-CU (2 monitors)

Diameter

0.65mm

0.8mm

1.0mm

Distance

35 m

50m

75m

AWG

22AWG

20AWG

18AWG

Distance

115’

160’

250’

IE-8MD to audio door station

Diameter

0.65mm

0.8mm

1,0mm

Distance

150m

230m

360m

AWG

22AWG

20AWG

18AWG

Distance

500’

750’

1,180’

Two farthest stations (any pair)

Diameter

0.65mm

0.8mm

1.0mm

Distance

75m

120m

190m

AWG

22AWG

20AWG

18AWG

Distance

250’

380’

630’

MY-CU/1E-8MD to power supply PS-18D(C)

Diameter

1.0mm

AWG

18AWG

Distance

5m

Distance

16’

-

6

-