PanTilt video integration to TD-H/A or B

The DE-UR adaptor connects MY-CU system

in the middle point of TD-H/A or B installation.

MYH-CU 1 MYH-CU 2

Wiring distance

From DE-UR to power supply

Between TD-H intercoms (any pair)

Diameter

0.65mm

0.8mm

1.0mm

Distance

10m

15m

20m

AWG

22AWG

20AWG 18AWG

Distance

30’

50’ 45’

Diameter

0.65mm

0.8mm

1.0mm

Distance

650m

1,000m

1,500m

AWG

22AWG

20AWG

18AWG

Distance

2,000’

3,000’

4,900’

From MY-CU to power suppiy

From MY-CU to MYH-CU #1 (2 monitors)

Diameter

1.0mm

Distance

5m

AWG

18AWG

Distance

16’

From MY-CU to PanTiit door MY-DC

Diameter

0.65mm

0.8mm

1.0mm

Distance

50 m

70m

100m

AWG

Distance

22AWG

20AWG

18AWG

165’

230’

330’

Diameter

0.65mm

0.8mm

1.0mm

Distance

35m

50 m

75m

AWG

22AWG

20AWG

18AWG

Distance

115'

160’

250’

From MY-CU to MYH-CU #2 (3 monitors)

Diameter

0.65mm

0.8mm

1.0mm

Distance

17m

25m

45m

AWG

22AWG

20AWG

18AWG

Distance

55’

80’

145’

-

7

-