INSTALLATION

Continued

NOTICE: Manual control heaters

may be used as a vented product.

If so, you must always run heater

with chimney flue damper open.

If running heater with damper

open, noncombustible material

above fireplace opening is not

needed. Go to Installing Damper

Clamp Accessory for Vented

Operation, page 12.

Minimum Noncombustible Material
Clearances
If Not Using Mantel
Note:

If using a mantel proceed to If Using Mantel.

If not using a mantel, follow the information on

this page.

You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2" thick. With sheet metal, you must have non-

combustible material behind it. Noncombustible

material must extend at least 8" up (for all models).

If noncombustible material is less than 12", you

must install the fireplace hood accessory (24" and

30" Models Only). See Figure 5 for minimum

clearances.
If Using Mantel

You must have noncombustible material(s) above

the fireplace opening. Noncombustible materials

(such as slate, marble, tile, etc.) must be at least

1/2" thick. With sheet metal, you must have non-

combustible material behind it. Noncombustible

material must extend at least 8" up (for all models).

If noncombustible material is less than 12", you

must install the fireplace hood accessory (24"

and 30" Models Only). Even if noncombustible

material is more than 12", you may need the hood

accessory to deflect heat away from your mantel

shelf. See Figure 5 and Figures 6 and 7, page 9,

for minimum clearances.
IMPORTANT:

If you cannot meet these minimum

clearances, you must operate heater with chimney

flue damper open. Go to Installing Damper Clamp

Accessory for Vented Operation, page 12.

Heat Resistant
Material

(A)

Figure 5 - Heat Resistant Material (Slate,

Marble, Tile, etc.) Above Fireplace

Noncombustible
Material

Requirements for

Distance (A)

Safe Installation

12" or more

Noncombustible mate-
rial OK.

Between 8" and 12" 24" or 30" Models:

Install fireplace hood
accessory (GA6050,
GA6052 or GA6053 see
Accessories, page 42).

18" Model: Noncombus-
tible material OK.

Less than 8"

Noncombustible mate-
rial must be extended to
at least 8". See Between
8" and 12", above. If you
cannot extend material,
you must operate heater
with flue damper open.

MANTEL CLEARANCES

In addition to meeting noncombustible material

clearances, you must also meet required clearances

between fireplace opening and mantel shelf. If

you do not meet the clearances listed below, you

will need a hood.
Determining Minimum Mantel Clearance

If you meet minimum clearance between mantel

shelf and top of fireplace opening, a hood is not

required (see Figure 6, page 11).
Determining Minimum Mantel Clearance
When Using a Hood

If minimum clearances in Figure 6, page 11, are

not met, you must have a hood. When using a hood

there are still certain minimum mantel clearances

required. Follow minimum clearances shown in

Figure 7, page 11, when using hood.