POSSIBLE CAUSE

1. Residues from manufacturing

processes and logs curing

1. Turning control knob to HI

position when burners are

cold

2. Air in gas line

3. Air passageways on heater

blocked

4. Dirty or partially clogged

burner orifice(s)

1. When heated, vapors from

furniture polish, wax, carpet

cleaners, etc. may turn into

white powder residue

1. Not enough combustion/ven-

tilation air

1. Battery is not installed. Bat-

tery power is low

1. Metal expanding while heating

or contracting while cooling

REMEDY

1. Problem will stop after a few

hours of operation

1. Turn control knob to LO

position and let warm up for

a minute

2. Operate burners until air is

removed from line. Have gas

line checked by local natural

or propane/LP gas company

3. Observe minimum installa-

tion clearances (see pages 9

through 11)

4. Clean burners (see Cleaning

and Maintenance, page 26)

or replace burner orifice(s)

1. Turn heater off when using

furniture polish, wax, carpet

cleaners or similar products

1. Refer to Air for Combustion

and Ventilation requirements

(page 6)

1. Replace 9-volt batteries in re-

ceiver and hand-held remote

1. This is normal with most heat-

ers. If noise is excessive, contact

qualified service person

OBSERVED PROBLEM

Slight smoke or odor during

initial operation

Heater produces a whistling

noise when burners are lit

White powder residue forming

within burner box or on adjacent

walls or furniture

Moisture/condensation noticed

on windows

Remote does not function (Re-

mote-Ready Models Only)

Heater produces a clicking/tick-

ing noise just after burners are

lit or shut off