Wiring diagram, Cleaning and maintenance – Desa VUL18 User Manual

Page 27

Advertising
background image

www.desatech.com

119426-01A

27

4. Check the injector holder located at the end

of the burner tube again. Remove any large

particles of dust, dirt, lint or pet hair with a

soft cloth or vacuum cleaner nozzle.

5. Blow air into the primary air holes on the

injector holder.

6. In case any large clumps of dust have now been

pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the

pilot flame indicates dust and dirt in the pilot as-

sembly. There is a small pilot air inlet hole about

2" from where the pilot flame comes out of the

pilot assembly (see Figure 41). With the unit off,

lightly blow air through the air inlet hole. You may

blow through a drinking straw if compressed air

is not available.

CLEANING AND

MAINTENANCE

Continued

LOGS

• If you remove logs for cleaning, refer to Install-

ing Logs, page 18, to properly replace logs.

• Replace log(s) if broken or chipped (dime-sized

or larger).

MAIN BURNER

Periodically inspect all burner flame holes with

the heater running. All slotted burner flame holes

should be open with yellow flame present. All

round burner flame holes should be open with a

small blue flame present. Some burner flame holes

may become blocked by debris or rust, with no

flame present. If so, turn off heater and let cool.

Remove blockage, blocked burner flame holes

will create soot.

Figure 40 - Injector Holder On Outlet

Burner Tube

Burner
Tube

Injector Holder

Primary Air
Inlet Holes

Ports/Slots

Figure 41 - Pilot Inlet Air Hole (Your pilot

may vary from pilot shown)

Pilot Air
Inlet Hole

Pilot Assembly

WIRING DIAGRAM

(Remote-Ready Models Only)

Thermopile

Advertising
This manual is related to the following products: