OPTIONAL POSITIONING

OF THERMOSTAT

SENSING bULb

(Thermostat-Controlled Models Only)

FOR MASONRY AND FACTORY-
BUILT METAL FIREPLACE

If your log set cycles to pilot, but the room tem-

perature drops to a lower than ideal comfort level

before the log set comes back on, you may want

to reposition the thermostat sensing bulb.

The thermostat sensing bulb is located on the gas

valve assembly. This location allows the ther-

mostat to keep the room temperature at an ideal

comfort level for most fireplace applications. For

positioning the thermostat sensing bulb elsewhere,

an adhesive-backed mounting clip is available

(see Figure 42).

Tools needed: 5/16" hex driver or socket

1. Locate the gas valve assembly and thermostat

sensing bulb (see Figure 43).

2. With 5/16” hex driver or socket, loosen the

thermostat screw. Carefully slide the thermo-

stat sensing bulb out of the retaining clamp

(see Figure 44).

Note: Do not remove the screw. Make sure

you tighten the screw after removing the

thermostat sensing bulb.

IMPORTANT: Do not force or bend the

thermostat sensing bulb or capillary.

Capillary

Screw

Retaining Clamp

Thermostat
Sensing Bulb

Figure 43 - Location of Gas Valve

Assembly and Thermostat Sensing Bulb

Thermostat
Sensing Bulb

Gas Valve
Assembly

Figure 42 - Adhesive-backed Mounting

Clip

Figure 44 - Removing Thermostat

Sensing Bulb

Figure 45 - Locating Thermostat Sensing

Bulb on Masonry Fireplace

Figure 46 - Locating Thermostat Sensing

Bulb on Factory-built Metal Fireplace

Adhesive-backed
Mounting Clip

Thermostat
Sensing Bulb

Figure 47 - Installing Thermostat Sensing

Bulb Behind Glass Doors

Adhesive-
backed
Mounting Clip

Glass Doors

Thermostat
Sensing Bulb

Adhesive-backed
Mounting Clip

Thermostat
Sensing Bulb

(Unit Will
Differ From
Illustration)

(Unit Will
Differ From
Illustration)

3. The thermostat sensing bulb may be located

to the lower right front side of fireplace. De-

termine location of sensing bulb, but do not

mount sensing bulb until step 4. If you have a

masonry fireplace, see Figure 45 for location.

If you have a factory-built metal fireplace, see

Figure 46 for location.

If your fireplace has glass doors, position

sensing bulb directly behind door gap on right

bottom side (see Figure 47).