10.8 RS-­‐485  Settings    

Purpose:    

The  RS-­‐485  serial  port  is  used  to  control  the  PTZ  of  the  camera.  The  configuring  of  the  PTZ  parameters  
should  be  done  before  you  control  the  PTZ  unit.    

Steps:    

1) Enter  RS-­‐485  Port  Setting  interface:    

Configuration>  Advanced  Configuration>  System  >  RS485      

 

 

Figure  10-­‐15

RS-­‐485  Settings    

2) Set  the  RS-­‐485  parameters  and  click  Save  to  save  the  settings.    

By  default,  the  Baud  Rate  is  set  as  9600  bps,  the  Data  Bit  is  8,  the  stop  bit  is  1  and  the  Parity  and  
Flow  Control  is  None.    

Note:  

The  Baud  Rate,  PTZ  Protocol  and  PTZ  Address  parameters  should  be  exactly  the  same  as  the  

PTZ  camera  parameters.    

 