ELECTRICAL SUPPLY CONNECTION

CAUTION: Disconnect the

electrical power to the supply

circuit before attempting to con-

nect or service this appliance.

WARNING: This appliance,

when installed must be electri-

cally grounded in accordance

with local code or in the ab-

sence of local code, with the

current National Electric Code,

ANSI/NFPA 70, or the Canadian

Electric Code, CSA C22.1.

A pre-wired junction box receptacle with strain

relief is provided on the right side of the cabinet

for hard wiring the unit to a 15 Amp, 120VAC,

60Hz grounded branch circuit. If the installation

demands that the electrical supply be connected

from the left side, the entire receptacle box can

be relocated to the left side by following these

instructions:
Note:

If you do not need to relocate the junction

box, to connect the electric supply follow steps 8

through 11 only:
1. Remove 2 screws and outer cover with strain

relief bushing on right side of cabinet (see

Figure 34).

2. Remove inner retaining screw on junction

box mounting tab.

3. Slide junction box up until screw mounting

tab is lined up to notch in outer cabinet.

4. Swing the junction box out and slip retaining

flange out through the slot in outer cabinet.

5. Remove two screws and outer cover on the

left side of the outer cabinet.

6. Reinsert junction box retaining flange through

slot now on the left side and swing screw

mounting tab back through notch as before.

7. Slide the junction box down till mounting tab

holes line up and replace the inner retaining

screw.

8. With junction box cover removed, pull the

end of 3-wire Romex supply line through

universal strain relief bushing on cover. (see

Figure 34).

9. Strip back the outer Romex to about 4" and

connect black, white and green wires accord-

ingly using 3 wire nut connectors.

10. Tuck tailing wires into junction box and

replace junction box cover using 2 remaining

screws.

11. Tighten down strain adjustment on universal

bushing until Romex sheathing is secured.

The electrical connection is now complete.

Figure 34 - Relocating Junction Box

Receptacle and Electrical Supply

Connection

J-Box Cover
with Strain
Relilef

J-Box
Cover

Romex
Cable

J-Box with
Receptacle

J-Box Cover with

Strain Relief

Screw/Tab
Retainer

INSTALLING OPTIONAL BLOWER
ACCESSORIES

NOTICE: If installing blower in

an existing fireplace with gas

connections, shut off gas sup-

ply and disconnect heater from

gas supply. Contact a qualified

service person to do this.

WARNING: If there is a du-

plex electrical outlet installed

in the right side of the bottom

of the fireplace base area, be

sure that the electrical power

to the outlet is turned off before

proceeding with blower instal-

lation. Failure to do this may

result in serious injury.

Model BK Installation

Follow all instructions provided in the blower

accessory kit.

1. Attach power cord to blower motor by firmly

pushing the two female terminals at the end of

power cord onto the two spade terminals on

blower motor (see Figure 35, page 22).