Replacement parts, Service hints, Technical service – Desa V)CD36RN User Manual

Page 44: Specifications

Advertising
background image

www.desatech.com

116035-01E

44

REPLACEMENT PARTS

Note:

Use only original replacement parts. This

will protect your warranty coverage for parts

replaced under warranty.

PARTS UNDER WARRANTY

Contact authorized retailers of this product. If

they can not supply original replacement part(s),

call DESA’s Customer Service Department at

1-866-672-6040.

When calling DESA, have ready

• your name

• your address

• model and serial numbers of your fireplace

• how fireplace was malfunctioning

• type of gas used (propane/LP or natural gas)

• purchase date

Usually, we will ask you to return the part to the

factory.

PARTS NOT UNDER WARRANTY

Contact authorized retailers of this product. If

they can not supply original replacement part(s),

call DESA at 1-866-672-6040 for referral infor-

mation.

When calling DESA, have ready

• model number of your fireplace

• the replacement part number

SERVICE hINTS

When Gas Pressure Is Too Low

• pilot will not stay lit

• burners will have delayed ignition

• fireplace will not produce specified heat

• propane/LP gas supply might be low (propane/

LP units only)

You may feel your gas pressure is too low. If so,

contact your local gas supplier.

TEChNICAL SERVICE

You may have further questions about installation,

operation or troubleshooting. If so, contact DESA’s

Customer Service Department at 1-866-672-6040.

When calling, please have your model and serial

numbers of your heater ready.

You can also visit DESA’s technical service web site at

www.desatech.com

.

SPECIFICATIONS

(v)CD36RN and (v)CD36TN

• Rating: 15,000/21,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Millivolt

• Manifold Pressure: below 2000 ft. elevation -

3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8"

(0.94 kPa)

• Orifice Size (Main Burner): #44 DMS (0.086")

• Minimum Inlet Supply Pressure: 5.5" w.c.

(1.1 kPa)

• Firebox Dimensions (HxWxD) (Flanges and

Standoffs Not Included in Measurement):

35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(v)CD36RP and (v)CD36TP

• Rating: 13,000/20,000 Btu/hr

• Gas Type: Propane/LP Gas Only

• Ignition: Millivolt

• Manifold Pressure: 10.0" w.c. (2.5 kPa)

• Orifice Size (Main Burner): #55 DMS (0.052")

• Minimum Inlet Supply Pressure: 11.0" w.c.

(2.7 kPa)

• Firebox Dimensions (HxWxD) (Flanges and

Standoffs Not Included in Measurement):

35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(v)CD36RNE and (v)CD36TNE

• Rating: 21,000 Btu/hr

• Gas Type: Natural Gas Only

• Ignition: Electronic

• Manifold Pressure: below 2000 ft. elevation -

3.5" w.c. (0.87 kPa), above 2000 ft. elev. - 3.8"

(0.94 kPa)

• Orifice Size (Main Burner): #44 DMS (0.086")

• Minimum Inlet Supply Pressure: 5.5" w.c.

(1.1 kPa)

• Firebox Dimensions (HxWxD) (Flanges and

Standoffs Not Included in Measurement):

35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)

(v)CD36RPE and (v)CD36TPE

• Rating: 20,000 Btu/hr

• Gas Type: Propane/LP Gas Only

• Ignition: Electronic

• Manifold Pressure: 10.0" w.c. (2.5 kPa)

• Orifice Size (Main Burner): #55 DMS (0.052")

• Minimum Inlet Supply Pressure: 11.0" w.c.

(2.7 kPa)

• Firebox Dimensions (HxWxD) (Flanges and

Standoffs Not Included in Measurement):

35 ¾"x 36 ¼" x 14 ¾"(908 x 921 x 375 mm)