LOCAL CODES

Install and use fireplace with care. Follow all local

codes. In the absence to local codes, use the cur-

rent National Fuel Gas Code ANSI Z223.1/NFPA

54* (USA) or the current CSA-B149.1 Installation

Code (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT FEATURES

These are a few facts that can help you understand

and enjoy your direct-vent fireplace:
• The CD36R dedicated rear vent is best suited

for flush or corner installations when vented

horizontally through an exterior wall.

• The CD36T dedicated top vent is suited for

any application where height is necessary to

terminate the venting system either through

the roof (vertical) or to gain sufficient height

and offset to vent to an outside/exterior wall

(horizontal).

• The vent pipe installation is very important to

allow for proper operation. You must select

the appropriate unit for your application and

follow the venting instructions to plan your

installation.

• This fireplace may be installed in any room of

your house provided all local codes and these

installation instructions are followed.

• Models (V)CD36R/T are equipped with a mil-

livolt gas control system that does not require

electricity to operate. A piezo ignitor is provided to

light the pilot without using matches or lighters.

• Models (V)CD36RE/TE are equipped with an

electronic ignition system that requires 120VAC

to operate. An electrode ignitor automati-

cally lights the pilot flame when the fireplace

is turned on.

• All models can accept an optional circulating

air blower when 120 VAC connection is sup-

plied. If you plan to install an optional blower,

do not forget to wire the fireplace outlet when

framing.

• Each time you turn on your fireplace, you may

notice some amount of condensation on the in-

side of the fireplace glass. This is normal and will

disappear after 10-20 minutes of operation.

Figure 2 - Common Fireplace Locations

Flush with

a wall

Through exterior wall

enclosed in a chase

Corner
installation

• Your direct-vent gas fireplace system (fireplace

and venting) is a balanced and sealed gas oper-

ating unit. It is highly efficient because it uses

outside air for combustion while independently

heating the indoor air.

PRE-INSTALLATION

PREPARATION

LOCATION AND SPACE
REqUIREMENTS

Determine the safest and most efficient location

for your DESA direct-vent fireplace. Make sure

that rafters and wall studs are not in the way of the

venting system. Choose a location where the heat

output is not affected by drafts, air conditioning

ducts, windows or doors. Figure 2 shows some

common locations. Be aware of all restrictions and

precautions before deciding the exact location for

your fireplace and termination cap.

When deciding the location of your fireplace,

follow these rules:

• Do not connect this fireplace venting to a chim-

ney flue serving a separate solid-fuel burning

fireplace or appliance.

• Due to high temperatures, do not locate this

fireplace in high traffic areas, windy or drafty

areas or near furniture or draperies.

• Proper clearances must be maintained.

• If your fireplace is to be installed directly on

carpeting, vinyl tile or any combustible material

other than wood, it must be installed on a metal

or wood panel extending the full width and depth

of the fireplace. See Figure 3, page 6.

• Your fireplace is designed to be used in zero clear-

ance installations. Wall or framing material can be

placed directly against any exterior surface on the

back, sides or top of your fireplace, except where

standoff spacers are integrally attached. If standoff

spacers are attached to your fireplace, these spac-

ers can be placed directly against wall or framing

material. See framing details on page 7.