Figure 3-12, Mode 2-single period measurement, Figure 3-13 – ADLINK USB-2401 User Manual
Page 50: Mode 3-single pulse-width measurement

40
Operation
software application. Operation in which initial count = 0,
count-up mode is shown.
Figure 3-12: Mode 2-Single Period Measurement
Mode 3: Single Pulse-Width Measurement
The counter calculates the pulse-width of the signal on
GPTC_GATE in terms of GPTC_CLK. Initial count can be
loaded from the software application. After software start, the
counter calculates the number of active edges on GPTC_CLK
when GPTC_GATE is in its active state.
After the completion of the pulse-width interval on
GPTC_GATE, GPTC_OUT outputs high and current count
value can be read by the software application. Operation in
which initial count = 0, count-up mode is shown.
Figure 3-13: Mode 3-Single Pulse-Width Measurement
0
0
1
2
3
4
5
5
5
Gate
CLK
Count value
Software start
0
0
1
2
3
4
5
5
5
Gate
CLK
Count value
Software start