4 sampling rate control, 5 timebase exporting, Sampling rate control – ADLINK PXI-2022 User Manual

Page 38: Timebase exporting, 30 function block and operation theory

Advertising
background image

30

Function Block and Operation Theory

4.3.4

Sampling Rate Control

By specifying different scan interval counter (32-bit) value, differ-
ent sam-pling rate can be achieved. The following formula deter-
mines the ADC sampling rate. Sampling Rate = TIMEBASE/Scan-
Intrv Where ScanIntrv is scan interval counter, value can be 4, 5,
6, 7, .... 2

32-1

.

Figure 4-5: Configuring Different Sampling Rate of PXI-2022.

4.3.5

Timebase Exporting

The PXI-2020/2022 can export timebase to one of the PXI trigger
bus line 0. By software programming, you can pick up a trigger line
to transmit timebase clock. This feature is very useful when syn-
chronize to multiple measurement modules.

TIMEBASE

DATA

D1

Acquisition

In Progress

Trigger

Acquisition starts right after this clock edge

D1

ScanIntrv = 1

D2

D3

D4

D5

D6

D7

D8

D9

D10

D2

D3

D4

D5

D6

D1

D2

D3

D4

ScanIntrv = 2

ScanIntrv = 3

Advertising