The internal voltage can be set to -5V or -10V which is selected by JP1 for 
the ACL-8112DG/HG and JP8 for the ACL-8112PG. Possible configurations 
are specified in Figure 2.9. Note that the internal reference voltage is used 
only when JP2 of the ACL-8112DG/HG or JP6 and JP7 of the ACL-8112PG 
is set to internal reference. 
Reference Voltage is
-5V (default setting)
JP1 /
JP8
-10V
-5V
Reference Voltage is
-10V
JP1 /
JP8
-10V
-5V
Figure 2.9 Internal Reference Voltage Setting
2.12 A/D Input Range Setting
(This section is for the ACL-8112PG only)
The A/D input range of the ACL-8112PG can be set to
±5V or ±10V using
JP9.
A/D Input Range is +/- 
5V (default setting) 
JP9
10
5
JP9
10
5
A/D Input Range is +/- 
10V 