25

Legend:

IDI_n: Isolated digital input channel #n.

IDO_n: Isolated digital output channel #n.

EICOM: Common Ground or Common power of isolated input

channels.

EOGND: Ground return path of isolated output channels.

VDD: Power supply of isolated output channels.

Figure 2-2: PCI-7230 Onboard Power and Ground terminal

Note:

The VDD must be supplied by an external power sup-
ply of 5 to 35VDC.