Installation ● 5

2

Installation

2.1 Power Budget Consideration

Prior to installing any cards into the PXIS-2700 chassis, please calculate
the system power requirement. The power budget for every DC power
sources shall also be checked, including +5V, +3.3V, +12V, -12V supply
rail. Please refer to Appendix A for the maximum usable power.

2.2 Step for Installation

Follow the step to power on the chassis.

Step 1: Make sure the power switch is in the OFF position.

Step 2: Plug in the AC power cord in each power supply unit.

Step 3: Install the controller. Please check the ejector/injector handle is

pushed down. Align the controller edge to the “RED” card guide,
sliding in to the rear of the chassis. Push up on the
ejector/injector handle to fully inject the card into the chassis.
Secure the screws on the module’s front panel.

Step 4: Install peripheral modules if any.

Step 5: Press the power switch on the front panel to power on the

chassis.

Step 6: Check the LED to make sure the power input is ready. There

are four green LED indicators of 3.3V, 5V, +12V, and -12V. The
four LED will light when power turn on. The fans should
become operational as well.

Note: If the chassis does not power on, see Chapter 4, troubleshooting and

Preventative Maintenance.