Troubleshooting and preventative maintenance – ADLINK PXIS-2700 User Manual

Page 19

Advertising
background image

Troubleshooting and Preventative Maintenance

13

4

Troubleshooting and Preventative
Maintenance

4.1 Troubleshooting the PXIS-2700

Please refer to Table 4.1 to troubleshoot the PXIS-2700 chassis. The
table lists possible causes for power failure and recommends ways to
correct the problem.

Table 4.1 Troubleshooting

Possible Cause

What to Do

PXIS-2700 is not
connected to power
source.

Make sure that the PXIS-2700 is connected to a live
electrical outlet. Try operating another piece of
equipment from this outlet.

Power switch is not
switched on.

Make sure that the power switch is set to the ON
position.

The Alarm Buzzer is
beeping

Push Alarm RST button to stop beeping and refer to
Chapter 2.3 to find out which alarm occurs.
z

Temperature LED flashes:

Cool down the PXIS-2700 system under 50

°C

z

Fan LED flashes:

Refer to Chapter 4.4 for the fan hot-swap
replacement

The Power Buzzer is
beeping

Check if both power supplies have power cord on it.
If either one of the power supply failed, please refer
to Chapter 4.5 for the power supply hot-swap
replacement.

4.2 Cleaning

Cleaning procedures consist of two parts, interior and exterior cleaning of
the chassis. Refer to your module user documentation for information
about cleaning the individual CompactPCI or PXI modules.

Advertising