NuDAM-6521

X. bit 1

Don’t care, set to 0

X. bit 0

0

Don’t append <CR> in output string

1 Append <CR> in output string(*Default

Setting)

Y. bit 3

Don’t care, set to 0

Y. bit 2

Don’t care, set to 0

Y. bit 1

Don’t care, set to 0

Y. bit 0

0

Odd parity (*Default Setting)

1

Even parity

Z. bit 3

0

Non-parity mode (*DefaultSetting)

1

Parity mode

Z. bit 2

0

One stop bit (*Default Setting)

1

Two stop bit

Z. bit 1 0

00 5 data bit format

01 6 data bit format

10 7 data bit format

11 8 data bit format

@Response
!(Addr)<CR>

or

?(Addr)<CR>

(Addr) Address

ID.

!

Command is valid.

?

Command is invalid. Invalid parameter values,
When you wanted to change the setting without
grounding the DEFAULT* pin.

Note :When you want to change the checksum or baud rate or

DataFlag, then the DEFAULT* pin should be grounded at
first.