IPMI User Guide

9.5

Communications with IPMC

Operating systems need to use a serial port to communicate with
the IPMC. The resource setting of the serial port must be IO:
0x3E8 and IRQ: 3. The communication setting of the serial port
must be BaudRate: 9600, DataBit: 8, ParityCheck: None, StopBit:
1, and FlowControl: None. In Windows XP, use “COM3” to com-
municate with the IPMC.

9.6

IPMI Sensors List

9.7

Relevant Documents

Sensor

Number

Sensor name

Normal

Reading

Remark

00h

BMC Watchdog

01h

3.3V

3.3 V

02h

5V

5 V

03h

12V

12 V

04h

SYSTEM Temp

25°C

05h

CPU Temp

40°C

06h

BIOS CHANGE

07h

BIOS POST ERROR

Document Title

Revision

Source

Intelligent Platform
Management Interface
Specification v2.0

Document Revision 1.1
February 20, 2002

Intel Corp.
http://www.intel.com/design/
servers/ipmi/spec.htm

PICMG 2.9 D1.0
CompactPCI System
Management Specification

January 21, 2000

Intelligent Platform
Management Bus
Communications Protocol
Specification v0.9

Document Revision 0.15
June 24, 1997

Intel Corp.
http://www.intel.com/design/
servers/ipmi/license_ipmi.htm