Output characteristics – ADLINK cPCIS-1100A Series User Manual

Page 40

Advertising
background image

36

Power Supply Unit

Dielectric Withstand: Meets IEC950 regulation

EMI: Meets EN55022 / FCC Class A

Hold-up Time: 5mS after power fail signal

Remote ON/OFF: Available at [INH#] & [EN#] pins

Power Fail Signal: Available at [FAL#] pin

Status LED: <Green> means valid input voltage; <Amber> means a
critical fault.

Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin

Power OK: Installed at all outputs

Leakage Current: Typ. 0.5mA

Output Characteristics

Output Current (A)

Output

Voltage

MIN.

MAX.

TYP.

PEAK.

5V

MAIN +VO1

@ ★ # ≡ ⊙

2.0 33.0 25.0

3.3V

AUX. +VO2

▲ @ ★ # ≡ ⊙

0 33 18 –

12V

AUX. +VO3

# ⊙ ★ @

0 5.5 5.5 6

-12V

AUX. –VO4

● ⊙ ★ ■ =

0 1 0.5

1.5

Symbol: "★" OVP built-in; "@" Adjustable; "#" Remote sensing;

"≡" 3rd-wire Load Sharing; "=" Droop Current Sharing;
"⊙" Installed with Or-ing diode; "▲" Magnetic Amplifier;
"●" Installed with Post-regulator; "■" Common Choke.


Remarks: Peak load sustainable for less than 60sec. with duty cycle <10%.

Max. load is the continuous operating load of each rail. Max. load
of each rail cannot be drawn from all outputs at the same time.


Advertising
This manual is related to the following products: