Output characteristics – ADLINK cPCIS-ET1100 Series User Manual

Page 44

Advertising
background image

38

Power Supply Unit

Power Fail Signal: available at [FAL#] pin

Status LED: <green> means valid input voltage; <amber> means a
critical fault.

Thermal Protection (OTP): Installed NTC and thermostat for thermal
sensor at [DEG#] pin

Power OK: Installed at all outputs

Leakage Current: 1.18mA at 254Vac/60Hz

Output Characteristics

Output Current (A)

Output

Voltage

Min.

Max.

Typ.

Peak.

5V

0 40.0

25.0

3.3V

0 40 20 –

12V

0 5.5 4 –

-12V

0 2 1 –

ƒ

Over Load Protection: fully protected against output overload or short circuit,

typical 120% max. load

ƒ

Over Current Protection: installed at each rail

o

Output Wattage: Typ. 250W continuous.

o

Output Connector: CompactPCI 47-pin power connector.

o

Line Regulation: Max. ±10mV

o

Load Regulation: 3.3V & 5V: ± 10mV, +12V: ± 30mV & -12V: -380
mV.

o

Noise & Ripple: 60 mV@5V and 3.3V output; 120mV@.± 12V
output.

o

OVP: Built-in at all outputs.

o

Adjustability: Available at VO1, 2 & 3.

o

Output Trim: Electrical trim available at VO1/VO2 [ADJ #].

o

Remote Sensing: Available at VO1, VO2 & VO3.

o

Hot-Swap:

Available.

o

N+1 Redundancy: Installed with internal OR-ing diodes at all outputs
for N+1 redundancy operation.

o

Current

Sharing:

Third-wire

current sharing at VO1,2 &3.

o

Power OK Signal: Available for all output.

Advertising